Digital Monitoring Products Inc PC0136 사용자 설명서
734W Installation Guide
Digital Monitoring Products
5
734W DEVICE NO:
7
734W Device Number
Enter a device number from 2-16 for the 734W. The device number must also be
programmed as a device in the panel. Default is 7.
734W
DHCP? NO YES
734W DHCP
Select YES (fourth select key) to use dynamic IP address information for the 734W IP
Address, Subnet Mask, and Gateway Address. Select NO (third select key) to enter static
IP information.
734W IP ADDRESS:
192.168.0.201
734W IP Address
Enter the IP address of the 734W. Default is 192.168.0.201.
SUBNET MASK:
255.255.255.0
Subnet Mask
Enter the local subnet mask assigned to the 734W. Default is 255.255.255.0
GATEWAY ADDRESS:
192.168.0.1
Gateway Address
Enter the local gateway address of the 734W. Default is 192.168.0.1
PANEL IP ADDR:
0.0.0.0
Panel IP Address
Enter the IP address of the panel. Default is 0.0.0.0.
Note: This IP address must match the address programmed in the panel at the Local IP
Address prompt in Network Options. The DHCP programming in the panel must be set to NO.
PANEL IP PORT:
2002
Panel IP Port
Enter the port number that the 734W uses to send communication to the panel. This must
be the same port that is programmed in 734W Listen Port in Network Options
programming of the panel.
734W PASSPHRASE
734W Passphrase
Enter an 8 to 16-character alphanumeric Passphrase to encrypt communication with the
panel. The 734W Passphrase must match the 734W Passphrase entered in Network Options
programming of the panel. The Passphrase is blank by default.
Note: A passphrase is required for communication to occur with the panel.
734W
ACCESS OPTIONS
Access Options
Press any select key to enter the Access Options menu. Press the CMD key to advance to the
Stop prompt. Press the back arrow to display the Communication menu.
ACTIVATE ZONE 2
BYPASS? NO YES
Activate Zone 2 Bypass
Select YES to activate the Zone 2 Bypass operation. Selecting NO allows standard zone
operation on Zone. Default setting is NO. If the door being released by the 734W module is
protected (contact installed), you can provide a programmable bypass entry/exit timer by
connecting its contact wiring to the 734W module Zone 2. When the on-board Form C relay
activates and the user opens the door connected to Zone 2, the zone is delayed for the
number of seconds programmed in ZONE 2 BYPASS TIME allowing the user to enter/exit during
an armed period.
If Zone 2 does not restore (door closed) within the programmed time, the piezo sounds every
other second during the last ten seconds. If Zone 2 restores prior to the end of the
programmed time, the piezo silences. If the zone does not restore before the programmed
time, the 734W ends the bypass and indicates the open or short zone condition to the panel.
ZONE 2 BYPASS
TIME:
40
Zone 2 Bypass Time
Enter the number of seconds to elapse before the Bypass Timer expires. Range is from 20
to 250 seconds. Press any top row select key to enter the number of seconds. If the door
remains open when the timer expires a zone open/short is sent to the panel for Zone 2.
The default is 40 seconds. Figure 10 shows how the Bypass option works.
5 Second
Strike
40-Second Zone 2 Bypass
entry/exit timer.
entry/exit timer.
10 seconds before
the bypass time expires,
the device beeps if
the door is still open.
End of
timer.
timer.
40
Seconds
A zone open/short is
indicated if the door
remains open.
Figure 10: Zone 2 Bypass Timeline using default time