Digital Monitoring Products Inc PC0181 사용자 설명서

다운로드
페이지 58
XTLplus Installation and Programming Guide 
Digital Monitoring Products
39
STOP
At the 
STOP option, pressing any select key allows you to exit the programmer 
function of the XTLplus panel. When selected, the panel performs an internal reset 
and exits the programmer. The Stop function causes the following conditions to 
occur:
• All 1100 Series DMP Wireless transmitters are reset to NORMALxx
• The panel’s Status List is CLEARED
During the Stop function, all keypad displays are momentarily disabled for two 
seconds. Afterwards, the programming function is terminated and the keypads 
return to the Status List display.
Set Lockout Code
35.1 
Set Lockout Code
Pressing COMMAND at the Stop option displays 
SET LOCKOUT CODE. This feature 
allows you to program a special code that will then be required to gain access to 
the panel’s internal Programmer through the keypad.
Changing the Lockout Code 
You can change this code at any time to any combination of numbers from 1 to 5 
digits long (1 to 65535). 
Do not use leading zeros for the lockout code.
1. Press any select key. The display changes to 
ENTER CODE: -.
2.  Enter a 1- to 5-digit code (do not enter a number higher than 65535). Press 
COMMAND.
3.  Enter the new Lockout Code again. Press COMMAND. The keypad display changes 
to 
CODE CHANGED.
Once you have changed the code, it is important that you write it down and store 
it in a safe place. Lost lockout codes require the panel to be sent back into DMP 
for repair. You may cancel a Lockout Code by entering 00000 at the Set Lockout 
Code command option.
Lockout Code restriction
Do not set a Lockout Code higher than 65535.
SET LOCKOUT CODE
SET LOCKOUT CODE