Laird Controls North America Inc. 818A 사용자 설명서
Command Pro Engineered Systems
User Manual
User Manual
34
142134
7.3.4 Changing the Transmitter ID Code
transmitters.
2. Remove the screws on the back of the transmitter and remove the back panel from the case. On ‘A’
Series IP67 rated transmitters, remove the battery door and batteries before removing the back of
the transmitter. On the belly box transmitters, open the battery compartment door.
the transmitter. On the belly box transmitters, open the battery compartment door.
3. Attach the programming plug to the 4-pin connector on the circuit board, or using the belly box
adapter, to the mini-DIN connector. Verify that the ID Code is displayed.
4. Enter the new ID Code and press the PRG key. The RAC16 display reads ‘SUCCESS’. Verify new ID
Code by pressing BKSP and ESC keys.
5. Reassemble the transmitter in reverse order, making sure that the battery wires do not get pinched
between the back panel and the case. Tighten the screws snugly. On ‘A’ Series IP67 rated
transmitters, replace the battery door and batteries after replacing the back panel. ‘A’ Series
captive screws should be tightened until snug, plus half a turn.
transmitters, replace the battery door and batteries after replacing the back panel. ‘A’ Series
captive screws should be tightened until snug, plus half a turn.
Refer to the RAC16 Series User Manual for more detailed instructions.