Crescend Technologies LLC UHFP10XXUL1 사용자 설명서
Copyright Crescend Technologies
2
Rev O
GENERAL DESCRIPTION
1.1. INTRODUCTION
This manual contains information and procedures for installation, operation, and general
maintenance of Crescend’s UHF Continuous Duty Power Amplifier.
This manual contains information and procedures for installation, operation, and general
maintenance of Crescend’s UHF Continuous Duty Power Amplifier.
1.2. PRODUCT
DESCRIPTION
The Crescend Technologies UHF RF power amplifiers are designed for trunking and conventional
repeater applications. Rack mountable and designed to accept a range of input powers for a given
rated output power, the amplifier covers a broad range of frequencies. Closed loop power control
is used to maintain a constant output power under varying voltage, signal input, frequency and
output load conditions. Several design features work to protect the amplifier under adverse
conditions.
The amplifier front panel includes status LED indicators for DC and Alarm conditions. RF Input,
RF Output, DC, summary alarm and power cutback connections are found on the back of the
amplifier. A fan is used to cool the amplifier.
Table 1-1. Amplifier Functional Specifications
Frequency Range:
403 – 470 MHz
Operating Voltage:
+13.8 ±0.7 Vdc
Current Consumption:
See Table 1-2
Duty Cycle:
100%
Power Input:
See Table 1-2 (Range Set at Factory)
Power Output (Single Carrier Operation):
See Table 1-2 (Set at Factory)
Power Output Change (Relatively set up value) + 1 dB (Maximum)
Input Return Loss:
-10 dB (Maximum)
Spurious & Harmonics:
- 65 dBc (Maximum)
Input/Output Impedance:
50 Ohms (Nominal)
Load VSWR Tolerance:
VSWR Protected above 3.5:1 (Nominal)
Input/Output Connector:
Type N Female
Vertical Mounting:
7.0 in
Horizontal Mounting:
19.0 in
Weight:
10 lbs (4.6 kg) (Nominal)
Cooling Method:
Fan Forced Air Over Heat Sink
Operating Temp. Range:
-30°C to +60 °C
Storage & Transport:
-40 °C to +70 °C
Humidity:
80% at +40 °C (Non-Condensing)
Altitude:
10,000 Feet (Maximum)
Front Panel Display:
INDICATORS
DC ON (Green), LOW OUTPUT (Red), HIGH
VSWR (Red), OVER TEMP (Red)
DC ON (Green), LOW OUTPUT (Red), HIGH
VSWR (Red), OVER TEMP (Red)
Alarm and Control Pins:
SUMMARY ALARM
Summary of Low Output, High VSWR, Over Temp
Alarms
CONTROLS
CTRL(Partial Power Cutback)
SH/D (External Power Control)
Summary of Low Output, High VSWR, Over Temp
Alarms
CONTROLS
CTRL(Partial Power Cutback)
SH/D (External Power Control)