Cisco Aironet 1240AG Series Access Point Hardware Installation Guide
OL-7293-01
Chapter 6      Troubleshooting
Low Power Condition
%CDP_PD-4-POWER_OK: Full Power - INJECTOR_CONFIGURED_ON_SOURCE inline power 
source—This message indicates the access point is operating at full power because it is connected 
to a Cisco switch that supports Intelligent Power Management and the switch has been configured 
with Power Inline Never.
%CDP_PD-4-POWER_OK: Full power - INJECTOR_CONFIGURED_LOCAL inline power 
source—This message indicates the access point is operating at full power because it has been 
configured to expect a power injector on this port. 
%CDP_PD-4-POWER_OK: Full Power - INJECTOR_DETECTED_PD inline power source—This 
message indicates the access point is operating at full power because it has detected a CDP packet 
from another Cisco powerable device (PD). The access point power is being supplied from a power 
injector or a non-Cisco power source because a Cisco power source does not transmit this type of 
CDP packet.
%CDP_PD-4-POWER_OK: Full Power - INJECTOR_DETECTED_MULTIPLE_MACS_ON_
HUB inline power source—This message indicates the access point is operating at full power 
because it has detected multiple Cisco devices. The access point power is being supplied from a 
power injector or a non-Cisco power source because a Cisco power source does not forward CDP 
packets. 
%CDP_PD-4-POWER_OK: Full Power - NON_CISCO-NO_CDP_RECEIVED inline power 
source—This message indicates the access point is operating at full power because it has not 
received any CDP packets within the timeout period. This condition indicates your access point is 
connected to a non-Cisco power source.
Note
To prevent possible over-current conditions, the power source must be an IEEE 802.3af 
compliant power source or an IEC60950 compliant limited power source.
%CDP_PD-2-POWER_LOW: All radios disabled - NEGOTIATED inline power source—This 
message indicates the access point is in low power mode with all radios disabled because the Cisco 
power source has indicated it is not capable of supplying sufficient power to the access point.
Note
A Cisco power injector might be required.
%CDP_PD-2-POWER_LOW: All radios disabled - LOW_POWER_CLASSIC inline power source 
platform=<platform name> MAC address=<xxxx.xxxx.xxxx>—This message indicates the access 
point is in low power mode with all radios disabled and has detected a Cisco switch that is unable 
to supply sufficient power to the access point. 
The< platform name> indicates the CDP device detected by the access point. The <xxxx.xxxx.xxxx> 
indicates the MAC address of the CDP device, typically, the switch port.
Note
A Cisco power injector might be required. The MAC address of the switch port must be used 
when configuring a power injector to this port.
%CDP_PD-2-POWER_LOW: All radios disabled- HIGH_POWER_CLASSIC_NOT_ 
CONFIGURED inline power source platform=<platform name> MAC address= 
<xxxx.xxxx.xxxx>—This message indicates the access point is in low power mode with all radios 
disabled and has detected a Cisco switch that does not support Intelligent Power Management, but 
should be able to supply sufficient power. The access point must be configured for pre-standard 
compatibility.