Axis PowerOver LAN Midspan 6-PT EUR 0169-012-01 전단
제품 코드
0169-012-01
©2005, Axis Communications AB. The Axis logo is registered trademarks of Axis Communications AB. All other company names and products
are trademarks or registered trademarks of their respective companies. We reserve the right to introduce modifications without notice.
are trademarks or registered trademarks of their respective companies. We reserve the right to introduce modifications without notice.
23737/EN/R1/0501
www.axis.com
Power over LAN Midspans & Active Splitters
Function
Deploying Power over LAN in conjunction with a central
UPS distributes back-up power and ensures uninterrupted
operation of network surveillance cameras during electrical
power failures.
UPS distributes back-up power and ensures uninterrupted
operation of network surveillance cameras during electrical
power failures.
Data rate
10/100 Mbps
Number of ports
1,6 or 12
Connectors
1 port Midspan: 1 shielded RJ-45 Data connector and 1
shielded RJ-45 output connector for the combined data and
power, TIA/EIA 568 Category 5
6 and 12 port Midspans: Shielded RJ-45, EIA 568A and EIA
568B, DB-9, Female (Management)
shielded RJ-45 output connector for the combined data and
power, TIA/EIA 568 Category 5
6 and 12 port Midspans: Shielded RJ-45, EIA 568A and EIA
568B, DB-9, Female (Management)
Scalability
Multiple Midspans can be mounted in a wiring cabinet to
support additional terminals, resulting in a simple, cost
effective method for expanding the network, as requirements
evolve
support additional terminals, resulting in a simple, cost
effective method for expanding the network, as requirements
evolve
Wiring
Midspans directly transfer data transmissions originating
from Ethernet terminals over pairs 1/2 and 3/6. It acts as
a normal patch panel for Ethernet connections, ensuring
continuous and reliable performance. Power is provided only
over unused Ethernet pairs 4/5 and 7/8
from Ethernet terminals over pairs 1/2 and 3/6. It acts as
a normal patch panel for Ethernet connections, ensuring
continuous and reliable performance. Power is provided only
over unused Ethernet pairs 4/5 and 7/8
Remote power
feeding
Powers network video products up to 100m (328 ft) by
utilizing existing Ethernet or fast Ethernet (category 5
unshielded or shielded twisted-pair cabling) for power
transfer
utilizing existing Ethernet or fast Ethernet (category 5
unshielded or shielded twisted-pair cabling) for power
transfer
Power over LAN
output specification
Pin assignment and polarity: 4/5 (RTN.), 7/8 (-V)
Output power voltage: -48 V
User port power: 15.4 W minimum
Aggregate power: 1 port Midspan: 23 W, 6 port Midspan:
100 W, 12 port Midspan: 200 W
Output power voltage: -48 V
User port power: 15.4 W minimum
Aggregate power: 1 port Midspan: 23 W, 6 port Midspan:
100 W, 12 port Midspan: 200 W
Input power
requirements
requirements
1 port Midspan:
AC input voltage: 90 - 264 V AC
AC Frequency: 47 - 63 Hz
AC input current: 0.5 A at 110 V AC, 60 Hz; 240 V AC, 50 Hz
6 and 12 port Midspans:
AC input voltage: 88 - 264 V AC
AC Frequency: 47 - 68 Hz
AC input current: 3.5 A at 110 V AC, 1.8 A at 240 V AC
DC input current: 10 A at 48 V
Volt ampere rating: 0.48 KVA (-48 V), 0.30 KVA (110 V AC)
AC input voltage: 90 - 264 V AC
AC Frequency: 47 - 63 Hz
AC input current: 0.5 A at 110 V AC, 60 Hz; 240 V AC, 50 Hz
6 and 12 port Midspans:
AC input voltage: 88 - 264 V AC
AC Frequency: 47 - 68 Hz
AC input current: 3.5 A at 110 V AC, 1.8 A at 240 V AC
DC input current: 10 A at 48 V
Volt ampere rating: 0.48 KVA (-48 V), 0.30 KVA (110 V AC)
Specifications Power over LAN Midspans
Installation and
management
Plug-and-play installation. Midspans automatically detect
all Power over LAN Ethernet terminals and supply inline
power.
Local LED management display
all Power over LAN Ethernet terminals and supply inline
power.
Local LED management display
Auto-sensing
algorithm
Standard IEEE802.3af auto-sensing algorithm, backward
compatibility to the pre-standard algorithm. This mecha-
nism automatically detects power-ready terminals and sup-
plies inline power. The per-port ensures continuous proper
operation of devices (e.g. Network Interface Cards (NICs)
that do no expect power on their Ethernet connection
compatibility to the pre-standard algorithm. This mecha-
nism automatically detects power-ready terminals and sup-
plies inline power. The per-port ensures continuous proper
operation of devices (e.g. Network Interface Cards (NICs)
that do no expect power on their Ethernet connection
Display and
indicators
All port interfaces are located on the front panel for easy
access and real-time network monitoring.
Bi-color LED, per port, indicating normal, overload or short-
circuit conditions.
System indicators: AC power, User indicator - Channel
power, Internal self-test monitoring LED,
6 and 12 port Midspans only: DC power
access and real-time network monitoring.
Bi-color LED, per port, indicating normal, overload or short-
circuit conditions.
System indicators: AC power, User indicator - Channel
power, Internal self-test monitoring LED,
6 and 12 port Midspans only: DC power
Compliance
IEEE802.3 standard (when no inline power is supplied) and
IEEE802.3af, DTE Power via Media Dependent Interface (MDI)
IEEE802.3af, DTE Power via Media Dependent Interface (MDI)
Mounting
1 port Midspan: Wall or shelf mounting
6 and 12 port Midspans: Prepared for 19”, 1U rack
installation
6 and 12 port Midspans: Prepared for 19”, 1U rack
installation
Approvals
CE compliance
FCC Part 15 Class B. EN55022 Class B (Emission),
EN50082-1 (Immunity)
Safety: UL 1950, CSA C22.2 No. 950, EN 60950
1 port Midspan: FCC Part 15 Class B with FTP cabling, (Class
A with UTP cabling), EN55022 (CISPR 22) Class B with FTP
cabling, (Class A with UTP cabling), Safety: GS EN 60950
6 and 12 port Midspans: TUV EN 60950
FCC Part 15 Class B. EN55022 Class B (Emission),
EN50082-1 (Immunity)
Safety: UL 1950, CSA C22.2 No. 950, EN 60950
1 port Midspan: FCC Part 15 Class B with FTP cabling, (Class
A with UTP cabling), EN55022 (CISPR 22) Class B with FTP
cabling, (Class A with UTP cabling), Safety: GS EN 60950
6 and 12 port Midspans: TUV EN 60950
Operating conditions
0 - 40ºC (32 – 104 ºF)
1 port Midspan: Humidity max 93%, non-condensing
6 and 12 port Midspans: Humidity max 90%, non-
condensing
1 port Midspan: Humidity max 93%, non-condensing
6 and 12 port Midspans: Humidity max 90%, non-
condensing
Thermal rating
6 and 12 port Midspans: 285 BTU
Dimensions (HxWxD)
and weight
1 port Midspan: 44 x 110 x 140 mm (1.75” x 4.17” x 5.5”),
450 g (1 lbs)
6 and 12 port Midspans: 44 x 433 x 302 mm
(1.75” x 17” x 11.9”), 4 kg (8.8 lbs)
450 g (1 lbs)
6 and 12 port Midspans: 44 x 433 x 302 mm
(1.75” x 17” x 11.9”), 4 kg (8.8 lbs)
Function
The Active Splitter separates the DC voltage and the
Ethernet data, into two separate outputs terminating at a
power port and a RJ-45 jack.
Ethernet data, into two separate outputs terminating at a
power port and a RJ-45 jack.
Connectors
12 V unit: Shielded RJ-45, EIA 568A and EIA 568B Circular
connector type HRS RP34
18 V unit: Shielded RJ-45
connector type HRS RP34
18 V unit: Shielded RJ-45
Power
Input 48 V nominal
12 V unit: Output 12 V, 0.9 A
18 V unit: Output 18 V, 0.38 A
12 V unit: Output 12 V, 0.9 A
18 V unit: Output 18 V, 0.38 A
Compliance
18 V unit: IEEE802.3af
Installation
Connects directly to the camera
Specifications Power over LAN Active Splitter
Approvals
12 V unit: EMCCISPR22 Class B, EN55022 Class B (Emission),
EN50082-1 (Immunity), 89/336/EEC, EMC Directive including
CE Mark, FCC Part 15 Class B. Canadian CSA C22.2, Class B
Safety: IEC 950, CB Certified, 73/23/LVD, CE Mark, EN60950,
TUV EN60950, AUL 1950. Canadian CSA C22.2, No. 950
18 V unit: FCC CFR47 Part 15B (Class B for FTP cables Class
A for UTP cables), EN 55022 (Class B for FTP cables Class A
for UTP cables)
Safety: UL60950:2000 EN60950/IEC 950, GS Mark
EN50082-1 (Immunity), 89/336/EEC, EMC Directive including
CE Mark, FCC Part 15 Class B. Canadian CSA C22.2, Class B
Safety: IEC 950, CB Certified, 73/23/LVD, CE Mark, EN60950,
TUV EN60950, AUL 1950. Canadian CSA C22.2, No. 950
18 V unit: FCC CFR47 Part 15B (Class B for FTP cables Class
A for UTP cables), EN 55022 (Class B for FTP cables Class A
for UTP cables)
Safety: UL60950:2000 EN60950/IEC 950, GS Mark
Operating conditions 12 V unit: 0 - 40 ºC (32 – 104 ºF)
Humidity max 90%, non-condensing
18 V unit: -20 - 55ºC (32 – 104 ºF)
Humidity max 93%, non-condensing
18 V unit: -20 - 55ºC (32 – 104 ºF)
Humidity max 93%, non-condensing
Dimensions (HxWxD)
and weight
12 V unit: 32 x 127 x 76.2 mm (1.26” x 5” x 3”), 175 g (5.6
oz)
18 V unit: 33 x 75 x 120 mm (1.26” x 3” x 4.8”), 220 g (7.1 oz)
For product configurations, please refer to http://www.axis.com/products/pol/list.htm