Example of RF exposure assessments
RF exposure is assessed based on calculation methods defined in international standards,
such as IEC 62232. Compliance assessment based on the equivalent isotropically radiated
power (EIRP) provide a conservative estimate of the compliance distance in the direction
of the main lobe of the antenna. Other methods, for example synthetic model calculations,
provide more accurate values in the near field of antennas as well as compliance distances
on each side of the antenna.
The EIRP is calculated based on the relationship between power density and EIRP as
follows:
S = EIRP ÷ (4πR
2
)
Where:
S
is the power density in mW/cm
2
R
is the distance to the center of radiation of the antenna in cm
EIRP
is in mW and EIRP = (Power input to the antenna in mW) × (Numerical gain of
the antenna)
Given the Alcatel-Lucent B25 RRH4x30 frequency of operation is 1930 MHz to
1995 MHz, then from Table 1 in Section 1.1310 the power density limit for general
population/uncontrolled exposure is 1 mW/cm
2
and the power density limit for
occupational/controlled exposure is 5 mW/cm
2
.
Therefore,
For the range of possible antenna and general population/uncontrolled exposure
operating parameters:
RF safe distance for 120 W total MIMO power with 15 dBi antenna and no cable
loss = 5.7 m in the main lobe.
RF safe distance for 120 W power with 6 dBi antenna = 2.0 m in the main lobe.
For a 19 dBi antenna, with 65° horizontal beamwidth, 6° vertical beamwidth, and
6° downtilt, using synthetic model simulations, the minimum safe distance for
general population/uncontrolled exposure is 8.5 m in the direction of the main
lobe and 3 m on each side of the antenna.
For the range of possible antenna and occupational/controlled exposure operating
parameters:
RF safe distance for 120 W total MIMO power with 15 dBi antenna and no cable
loss = 2.6 m in the main lobe
RF safe distance for 120 W power to the antenna with 6 dBi antenna = 0.9 m in
the main lobe.
For a 19 dBi antenna, with 65° horizontal beamwidth, 6° vertical beamwidth, and
6° downtilt, using synthetic model simulations, the minimum safe distance to the
antenna for occupational/controlled exposure is 2.5 m in the direction of the main
lobe and 0.6 m on each side of the antenna.