Honeywell International Inc. KSN770 사용자 설명서

다운로드
페이지 248
Draft
Page 2-50
6 Dec 2012
34-70-06
SYSTEM INSTALLATION MANUAL
066-01204 / 066-01213
© Honeywell International Inc. Do not copy without express permission of Honeywell.
On dual VOR/ILS installations, it is recommended that a splitter be used to divide signals from a single 
VOR/LOC antenna into two or more receivers. Use double shielded cables to reduce interference to 
the receivers.
Prepare the cable to the BNC connector as shown in Figure 2-6.
2.5
Optional Accessory Installation
2.5.1
External Annunciators
The recommended external annunciator for the KSN 7xx is the Mid Continent MD41-TBD (refer to the 
Mid Continent installation manual for installation instructions).
2.5.2
External Switches
External switches may be added for functions such as external increment and decrement of channel 
frequencies. Unless otherwise noted, these are signal level inputs and may be activated using MS 
25089-1C Normally Open switches or equivalent necessary for system operation.
2.6
Magnetic Compass Recalibration
After the KSN 7xx has been installed and is operational, be sure to recalibrate the magnetic compass.
Draft as of 10/15/2012
Section 2.5.1 
We do not want to be tied down to only one Brand and Model of 
External Annunciators.  Is the MD 41 the only option? 
Section 2.5.2 
Same comment for External switches as 2.5.1.