5.16.4 Channel Change Parameter
The “CHNG CHAN” menu parameter selects the conventional channel to be
reprogrammed. Disabled or P25 Trunked/SMARTNET/SmartZone channels cannot be
selected. This does not change the channel selected for normal operation.
reprogrammed. Disabled or P25 Trunked/SMARTNET/SmartZone channels cannot be
selected. This does not change the channel selected for normal operation.
Press the Select switch to display “CHNG CHAN” and then scroll through the
programmed channels by rotating that switch. When the desired channel is displayed,
select it by pressing the Select switch.
programmed channels by rotating that switch. When the desired channel is displayed,
select it by pressing the Select switch.
5.16.5 System Parameters
Note
If “PASSWORD” is briefly displayed when attempting to select a parameter, see
Section 5.16.2.
Section 5.16.2.
The “SYS PARMS” menu parameter selects the conventional mode timer to be
reprogrammed (see following). Press the Select switch to select “SYS PARMS” and then
rotate that switch to display the desired parameter. Then press the Select switch again to
select it.
reprogrammed (see following). Press the Select switch to select “SYS PARMS” and then
rotate that switch to display the desired parameter. Then press the Select switch again to
select it.
SCAN TIMER - Selects the Scan Hold timer. Rotate the Select switch to decrement/
increment the timer in 0.5-second steps from 0-7.5 or set it to 0 seconds to disabled it.
When the desired value is displayed, store it by pressing the Select switch.
increment the timer in 0.5-second steps from 0-7.5 or set it to 0 seconds to disabled it.
When the desired value is displayed, store it by pressing the Select switch.
TX TIMER - Selects the transmit time-out timer. Rotate the Select switch to
decrement/increment the timer in 15-second steps from 0-225 or disable it by selecting
0 seconds. When the desired value is displayed, store it by pressing the Select switch.
decrement/increment the timer in 15-second steps from 0-225 or disable it by selecting
0 seconds. When the desired value is displayed, store it by pressing the Select switch.
PEN TIMER - Selects the penalty timer. Rotate the Select switch to decrement/
increment the timer in 15-second steps from 0-225 or disable it by selecting 0 seconds.
When the desired value is displayed, store it by pressing the Select switch.
increment the timer in 15-second steps from 0-225 or disable it by selecting 0 seconds.
When the desired value is displayed, store it by pressing the Select switch.
CONV TIMER - Selects the conversation timer. Rotate the Select switch to decrement/
increment the timer in 30-second steps from 0-450 or disable it by selecting 0 seconds.
When the desired value is displayed, store it by pressing the Select switch.
increment the timer in 30-second steps from 0-450 or disable it by selecting 0 seconds.
When the desired value is displayed, store it by pressing the Select switch.
5.16.6 Channel Parameters
Note
If “PASSWORD” is briefly displayed when attempting to select a parameter, see
Section 5.16.2.
Section 5.16.2.
The “CHAN PARMS” menu parameter selects the following conventional channel
parameters that can be reprogrammed. Press Select switch to select the “CHAN PARMS”
parameter and then rotate that switch to display the desired parameter. Then press the
Select switch again to select it. The squelch control parameters are unique to the type of
conventional channel selected (analog or Project 25).
parameters that can be reprogrammed. Press Select switch to select the “CHAN PARMS”
parameter and then rotate that switch to display the desired parameter. Then press the
Select switch again to select it. The squelch control parameters are unique to the type of
conventional channel selected (analog or Project 25).