E F Johnson Company 2425720 사용자 설명서

다운로드
페이지 168
Viking™ VP600 Portable Radio Operating Manual
6-13
SmartNet / SmartZone / P25 Trunked Features
If the preceding Emergency Hot Mic feature is enabled, the call is automatically 
transmitted without pressing the PTT switch. If it is disabled, press the PTT switch and 
begin speaking as with a standard call.
All group calls which follow are then emergency calls (unit, telephone, and call alert 
calls are not allowed). If the channel is changed, the call is made on the emergency 
talkgroup programmed for the new channel. If the Surveillance Mode is enabled (see 
Section 4.10, Surveillance Mode), the radio will behave in accordance to the individual 
surveillance mode options. If “No Rx Activity During Emergency” is programmed, 
receive audio and the front panel LED are disabled in the receive mode.
To exit this mode, cycle radio power or press and hold the Emergency button.
6.8.4 External Emergency Feature
A special man-down switch (currently available only from third-party vendors) is attached 
to the accessory connector of the radio. If this feature is enabled by programming and the 
radio is in a horizontal position for longer than the programmed time (0 to 63 seconds), an 
emergency condition is triggered the same as if the Emergency button was pressed. The 
emergency can be canceled by pressing and holding the Emergency button. Note that 
accessories such as speaker-microphones cannot be used with this feature.
6.9
Failsoft Operation
If a failure occurs in the SmartNet/SmartZone or P25 Trunked system so that system 
traffic cannot be centrally managed, the system directs the radio to automatically enter the 
failsoft mode. When in this mode, “Failsoft” is displayed. A failsoft tone may also be 
heard, depending on how the repeater is programmed.
When in the failsoft mode, operation is in the conventional mode on the pre-programmed 
failsoft channel (a different failsoft channel can be programmed on each talkgroup). If a 
transmission is attempted before a failsoft channel is located, a continuous tones sounds 
until the PTT switch is released. When the radio system returns to normal operation, this is 
automatically detected and normal operation resumes.
Console 
Acknowledgement
Emergency Alarm 
Ack
Emergency Alarm 
Acknowledged 
Successful
Two 1000 Hz 175 ms tones with 
50 ms spacing followed by Three 
1000 Hz 175 ms tones with 150 
ms spacing
Emergency Alarm 
Entry
Emergency Button 
Press
Emergency button has 
been Pressed
1000 Hz continuous tone for 175 
ms.
Emergency Exit
Emergency Canceled Emergency is 
Canceled
1000 Hz continuous tone for 1 
sec.