E F Johnson Company 2425720 사용자 설명서

다운로드
페이지 168
Viking™ VP600 Portable Radio Operating Manual
8-7
Secure Communication (Encryption)
8.4.1 Motorola Third-Party RNC Registration
The Viking VP600 radio supports Motorola dynamic data registration. However, if 
desired, the radio can be programmed to perform MOT 3rd Party data registration instead 
of dynamic registration on the OTAR and Data parameters page. If MOT 3rd Party 
registration is selected, the radio must be manually registered on the Motorola RNC 
Console by entering the following command:
LCRD 03 06 00 1234 7F xx xx xx 0A 0A 00 07 00 yy
Where, “xx xx xx” is the hex value of the Digital Unit ID programmed. Refer to the 
console documentation for the value of “yy” or use “00”. This registration needs to be 
done only once.
8.4.2 Programming By Keyloader
The following are the minimum parameters that need to be programmed in the radio to 
perform OTAR. It is not necessary to program a TEK to perform OTAR. If the radio does 
not contain a TEK, the KMF initiates a warm start sequence in which a temporary TEK is 
transferred to the radio to perform the key transfer.
UKEK - This key normally has SLN (CKR) 61440 and Key ID 62880 (F5A0 hex). 
Create a key (either AES or DES type as required) and download it to the radio. AES 
UKEKs typically use an SLN of 61442 and a Key ID of 62880 (0xF5A0).
Unit RSI - This is normally initially the same as the P25 Unit ID and is set by 
programming.
KMF RSI - This RSI is normally 9,999,999 and should not need to be loaded since it 
defaults to this number.
MNP (Message Number Period) - Load the proper message number period into the 
radio (typically 1000).
Verify that the above information was properly stored in the radio by viewing it using the 
keyloader.