Viking™ VP600 Portable Radio Operating Manual
Radio-wide Features
An Out of Range Beacon can be programmed for the Fire Commander in five second 
intervals from 5 – 80 seconds. When programmed, the Fire Commander will send out a 
beacon at the programmed interval. An Out of Range Indicator can be programmed for the 
First Responder in five second intervals from 7 - 82 seconds. When programmed, if the 
First Responder fails to receive a beacon from the Commander for the programmed 
duration, the First Responder will emit an OOR tone and display “Out of Range” on the 
display until a carrier event with an RSSI level above the OOR RSSI threshold is received. 
Note
The slight offset between timers is necessary to avoid the radio momentarily going out of 
range and then back in range. 
Communications Check can be programmed to any radio, but is intended for, and only 
works with Fire Mode radios. Only radios that are optioned for Fire Ground First 
Responder, and currently in Fire Responder mode, can issue a “Comm Check.” When 
pressed, the responder will sound one of several tones to indicate the RSSI range the 
Responder radio is currently in. This feature will only work on digital channels and can 
only be programmed as a function button. 
When the “Comm Check” button is pressed on a Responder radio, the Responder requests 
the current RSSI level from the Commander radio. If in range, the Commander radio will 
respond with the RSSI level. If the RSSI level is Excellent or Good, the Responder will 
sound a Talk Permit Tone. If the RSSI level is Fair, the Responder radio will sound two 
beeps. If the RSSI level is Poor or OOR, the Responder radio will sound four beeps.  
Please refer to the Conventional RSSI Guide for a list of RSSI thresholds to use when 
programming this feature.
This feature makes use of the P25 Signaling Retry Attempts and Retry Response Timer 
settings defined for the radio. If the Comm Check retries to completion and the Responder 
Out of Range Indicator feature is enabled, the radio will go Out of Range. If not enabled it 
will display No Ack for two seconds. 
Comm Check works in either simplex mode or through a repeater configured for data 
repeat mode, both of which require a Responder and Commander radio. Currently the 
EFJohnson infrastructure does not support the process of Comm Checks so a Commander 
radio is required.
Evacuation Alert can be programmed to any radio, but is intended for, and only works 
with Fire Mode radios. The Evac Alert is sent by the Fire Commander radio and received 
by the Fire First Responder. The Fire First Responder radio will warn the user with an 
Evac Alert tone and message to notify the user to evacuate. This feature will only work on 
digital channels and can only be programmed as a function button.
Any radio can program an Evac Alert button; however, only subscribers that are optioned 
for Fire Ground Commander, and currently in Fire Commander Mode, can issue an Evac 
Alert. A press and hold is required for activation. If an Evacuation Alert message is 
received by the Fire Responder radio, the subscriber will flash “Evac Alert” on the display 
and sound the Evacuation Alert tone.