General Operation
With Project 25 operation, a NAC is transmitted which must match the NAC programmed 
in the repeater or base station equipment and the radio(s) being called for communication 
to occur. In addition, to receive standard group calls, the receiving radio must be 
programmed to detect the transmitted talkgroup ID code.
With conventional operation, a busy channel condition is detected automatically if the 
busy channel lockout (transmit disable on busy) feature is programmed. Otherwise, it must 
be detected manually. An out-of-range condition is not indicated by special tones or 
messages as with trunking operation because there is no initial data exchange with the 
repeater that allows this condition to be detected. Operating features unique to 
conventional channels are described in Section 5.
3.11.2 SmartNet / SmartZone Mode
This is a trunked operating mode in which automatic access is provided to several RF 
channels. ID codes are used to select what radios are being called and what calls are 
received. Monitoring is performed automatically and special messages and tones indicate 
busy and out-of-range conditions.
SmartNet and SmartZone operation and programming is very similar. Basically, SmartNet 
operation is limited to a single repeater site and SmartZone operation allows automatic 
roaming between sites. Enhanced SmartNet/SmartZone features include roaming 
(SmartZone only), telephone, private, and emergency calls, Call Alert™, and messaging. 
Either analog or digital signaling may be used (digital is optional).
When a SmartNet or SmartZone channel is selected or the radio is powered up on one of 
those channels, the alias (name) of the selected channel is displayed as the radio searches 
for a control channel. Once a control channel is found, the radio attempts to register on the 
trunked system. If a control channel could not be found (because of an out of range 
condition or the system ID is not correct, for example), “No Sys” (early units) or “Out Of 
Rnge” (later units) is displayed and the radio continues to search for a control channel.
The control channel transmits and receives system information to and from all radios 
registered on the system. Therefore, once a control channel is found, it is continuously 
monitored for incoming call information and is used to make call requests. The radio 
automatically changes to a traffic channel to place and receive calls and then returns to the 
control channel when the call is complete. Operating features unique to SmartNet/
SmartZone channels are described in Section 6.
3.11.3 P25 Trunked Mode
The P25 Trunking operating features are very similar to the SmartZone type. Some 
differences between the P25 Trunking and SmartZone modes are as follows:
Preliminary Draft 3/9/12