DC Filter
The DC filter unit is the interface for +24 V DC power supply or battery backup.
Number of units: 0–1
6.2
Optional Hardware Units
This section describes the optional RBS 2207 hardware units.
Bias injector
The bias injector is used to provide the ddTMA with DC power, from the
TMA-CM, over the RX/TX feeder cables. Six bias injectors can be connected
to one TMA-CM. The BIAS-IC is mounted outside the cabinet, as close to the
RF output as possible.
Number of units: 0–6
BBS
The RBS 2207 can be provided with battery backup from an external cabinet,
either a BBS 2000 or a BBS 2202 equipped with BFU-21 or BFU-22.
ddTMA - dual duplex Tower Mounted Amplifier
The ddTMA is to be mast-mounted and placed close to the antenna. It improves
the receiver sensitivity. The ddTMA saves feeder cables by duplexing RX and
TX signals to the same cable.
Number of units: 0–6
TMA-CM - Tower Mounted Amplifier - Control Module
The Control Module is used to provide up to six ddTMAs with 15 V DC power
through the bias injector. It is also used to identify TMA faults and forward this
information to the alarm module in the RBS.
Number of units per cabinet: 0–1
RX-Splitter 01
RX-Splitter 01 distributes the receiver signals from the CDUs to the dTRU
in specific configurations of the RBS.
Number of units per cabinet: 0–1
7
Interfaces
In this section all external and internal connections are listed, as well as the test
interface and the operator interface.