8
Power System
The power system of the RBS 2207 depends on the choice of power supply
and may include a number of units outside the RBS.
The RBS 2207 can be connected either to AC mains supply voltage or to DC
supply voltage.
Table 8
Power Supply Voltage Alternatives
Nominal Voltage
PSU
120–250 V AC, 50–60 Hz
PSU-AC
+24 V DC
PSU not needed
48 to
60 V DC
PSU-DC
Note:
It is mandatory that a readily accessible disconnect device is
incorporated in the fixed wiring. The disconnect device must
disconnect all live wires from the cabinet.
8.1
AC mains supply voltage
AC mains supply voltage is connected to the cabinet using two AC cables.
If the power supply does not meet the AC power requirements, then filters
and stabilizers must be installed to protect the equipment and ensure proper
operation.
There are two ways to connect power to the RBS. They are:
Single phase line to neutral
Single phase line to line
Note:
When single phase line to line is used, each PSU requires two circuit
breakers or fuses.