4 Installation
ID No: 159967
Page 19
4.1.2.  Wall Mounting Procedure
  Check the suitability of the wall mounting kit and the wall.
F
 Note:
To ensure sufficient airflow when mounting the unit in enclosed
spaces, two lid openings (one for the air inlet and the other for the
air outlet) have to be provided. The size of each opening must equal
at least 12x12 cm (144 cm
2
). Also, make sure there is no thermal
short circuit between the air inlet and air outlet.
  Mark the position of the drilling
holes (for measurements refer to
figure 4-2 Wall mounting). Drill
four holes at the marked positions
and insert dowels*.
  Use a cap nut or locknut to screw
the four dowel screws into the
dowels and put the distance tubes
over the screws.
  Hang the mounting brackets of the
remote unit into the screws, and
fasten them immediately using the
washers and nuts.
  Ensure that there is free access to
the electrical connections as well
as to the cabinet. The approved
bending radius of the connected
cables must not be exceeded.
figure 4-2 Wall mounting
* The dowels are not part of the delivery since the suitable type depends on the on-site conditions
(material of wall). Therefore, use dowels that are appropriate for the mounting surface.