Sanitag Technologies Corporation AT004H 사용자 설명서

다운로드
페이지 23
  
 
Setting Up Devices & RF Netwowk 
 
 
 
 
 
1-8 
 
 
 
 
 
 
 
THIS DOCUMENT IS THE PROPERTY OF SANITAG COMPANY. IT MAY NOT BE COPIED AND REPRODUCED WITHOUT WRITTEN PERMISSION OF SANITAG 
COMPANY. COPYRIGHT NOTICES MAY NOT BE REMOVED 
 
         Note: This equipment has been tested and found to comply with the limits for a Class B   
         digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 
         reasonable protection against harmful interference in a residential installation. This  
         equipment generates, uses and can radiate radio frequency energy and, if not installed   
         and  used in accordance with the instructions, may cause harmful interference to radio     
         communications.However, there is no guarantee that interference will not occur in a   
         particular installation. If this equipment does cause harmful interference to radio or  
         television reception, which can be determined by turning the equipment off and on, the    
         user is encouraged to try to correct the interference by one or more of the following  
         measures: 
 
         
—Reorient or relocate the receiving antenna. 
         
—Increase the separation between the equipment and receiver. 
         
—Connect the equipment into an outlet on a circuit different from that to which the  
         receiver  is connected. 
         
—Consult the dealer or an experienced radio/TV technician for help. 
 
 
1.1.5. 
Active RFID Tag for Assets (Sanitag Model No: AT-003-H) 
 
It  has  two  leds  (Green,  Red)  If  device  is  powered  up  ,  Green  led  blinks  by  each 
wake/sleep  cycle.  There  is  no  led  indication  in  stand-by  mode.  It  has  one  button  with 
following functions: 
 
  Button Short Press/Release : Send Emergency Message / Wake the device up if 
in stand-by 
  Button Press for 5 Seconds: Enter to standby mode. 
 
 
Sanitag  AT-003-H  device  has  2.4GHz  RF  propagation  that  2.5dBm  output  power  level 
and  it has 2,4 GHz Pcb antenna. Also, AT-003-H device has UWB module that has 3.1 ~ 
8 GHz monopole antenna. We operation  at 4.4GHz due to special reason. UWB Module 
output power is fully adjustable from 0 dBm to 15.5 dBm via firmware.  
 
The 
device’s both of PCB antenna and UWB monopole antenna are omnidirectional. Both 
of antenna are fixed on PCB
, that's why İt cannot change reorient and relocate. 
Therefore  AT-003-H 
can  take  signal  every  direction.  İf  Sanitag  AT-003-H  obstructs  by 
obstacle of in Table 1.  The 
device’s RF signal will decrease as stated in Table 1. 
AT-003-H can transmit until 200 meters to readers if RF output power is fully.  
 
          THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS              
          SUBJECT TO THE FOLLOWING TWO CONDITIONS. 
  
          (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS     
          DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING    
          INTERFERENCE   THAT MAY CAUSE UNDESIRED OPERATION. 
 
          Warning: Changes or modifications not expressly approved by the party responsible for  
          
compliance could void the user’s authority to operate this equipment.