3B TECH Inc COOL-P800 사용자 설명서

다운로드
페이지 12
14
RolliBot RolliCool Mini-Split AC User Manual
Ensure that the rubber stopper is placed in a suitable location. If the Indoor and Outdoor Units are disconnected e.g. when 
the unit is being moved, the rubber stopper should be reinstalled into the end of the Coupler. If separating the two, review 
the following section.
3.3 – Connecting the Coupler
Step 1.
Unscrew the screw at the right side of the 
cover. Push the button at the right side of the 
cover and pull it away from the unit to remove 
it.
Step 2.
Remove the rubber stopper from the end of 
the Coupler if it is installed. Open the latch 
and line the Coupler up with its connectors.
Step3.
Make sure the Coupler is properly threaded 
into its connectors and push it straight down.
Step 4.
Slowly close the latch, taking care to use even 
pressure on the latch.
Step 5.
Connect the power cable to the inside of the 
unit.
Step 6.
Replace the Coupler Cover. Make sure to add 
the screw.
Cover
Power Cable
Keep the Coolant
Lines straight
11
RolliBot RolliCool Mini-Split AC User Manual
Section 3. Setting Up the AC
3.1 – Installing the Indoor Unit
• Choose a mounting location situated next to a window as the Coolant Lines must be run through a window in order to 
keep the Indoor and Outdoor Units connected.
• Using a stud detector for detection and installation into wall studs may be desired for more secure mounting.
Step 1.
 Choose a suitable 
location on the wall for 
mounting the unit. 
Step 4.
Use a drill to make 4 holes at each of the marks.
Step 5.
Insert the Wall Anchors into the wall.
Step 6.
Add the screws into their anchors making sure a length of 
4mm~9mm is left out of the wall.
Step 7.
Install the Indoor Unit onto the wall making sure the
notches in the Mount Openings slide over the screws.
Step 8.
Check to ensure the Indoor Unit is securely installed on the 
wall.
Step 9.
Remove the Indoor Unit for now to prepare for connection.
After installing the Outdoor Unit (Section 3.2) and Connecting
the Coupler (Section 3.3), reinstall the Indoor Unit on the wall.
Step 2.
 Measure between the 
Mount Openings on the back 
of the unit.
Step 3.
 Mark locations on 
the wall according to the 
openings.
H
L
Rollibot-MiniSplitAC-UM-0403.indd   Spread 11 of 12 - Pages(14, 11)
Rollibot-MiniSplitAC-UM-0403.indd   Spread 11 of 12 - Pages(14, 11)
4/10/2017   7:41:36 PM
4/10/2017   7:41:36 PM