Forced Search
If you use the Forced Search function, the transceiver 
searches for other Control channels using the following 
hunt sequences.
Hunt sequence
Explanation
Preferential Hunt Sequence
The transceiver searches for a Control channel that is set as the 
Preferential Hunt Control channel.
The transceiver selects this Control channel with a high priority.
Normal Hunt Sequence
The transceiver searches for a Control channel that is set as the 
Normal Hunt Control channel.
System Add Channel Sequence
The transceiver searches for up to 8 Control channels that are 
added by the system.
Site Hunt Sequence
The transceiver searches for a Control channel that is set as the 
Site Hunt Control channel in each site.
Comprehensive Hunt Sequence
The transceiver searches for a Control channel that is set in the 
network frequency table.
 Hold down [Forced Search Function] for 2 seconds 
 
q
to turn ON the Forced Search Function.
  • Displays the current site number.
 The transceiver starts to search for a Control chan-
 
w
nel signal.
  • Displays “SEARCHING.”
 When the transceiver finds and registers to a control 
 
e
channel, the normal screen is displayed on the func-
tion display.