Orient the pump so that the timer is accessible. The timer should never be
positioned in any orientation above the pump housing.
6.
Make sure that the screw ring that attaches the motor to the pump is
securely hand tightened. Do not attempt to further rotate the pump timer
or the pump may be damaged.
Over-tightening the pump screw ring can cause damage to the pump. Do
not use pipe compound or plumber's putty on the screw ring.
7.
Turn on the water supply to the hot water source and verify that there are
no leaks at any connections.
8.
Turn on the faucet/taps or shower farthest from the hot water source until
there is a steady stream of water with no sputter or evidence of air in the
lines.
9.
Plug the pump cord into the wall outlet and start the system. In the event of
a disruption in the power supply, the ACT–4 wireless pump will resume
communication with the paired mixing valve.
10. Open the timer cover. Rotate the dial clockwise until the current time is
aligned with the pointer at the top (12 o'clock position) of the dial.
See Thermostat Controlled Operation PLUS Timer section below.