Product Manual 
SCC1000 – Smart Connector 
 
ND 7942-1 11/2014 
Users Manual – SCC1000 Smart Connector 
 
Page 3 
 
www.idealindustries.com 
Fig. 2. 
4.
 For feed-through (i.e., “daisy-chain”) installations, insert the LINE hot feed-through conductor 
into the other black line port.  Insert the LINE neutral feed-through conductor into the other 
unmarked LINE port.  See Fig. 2. 
5.
 After LINE wire installation, the supply power can safely be disconnected and re-connected 
without re-installing the wires.  To disconnect the supply power, firmly grip the LINE 
connector and pull to separate it from the main body of the Smart Connector.  To re-
connect, simply push the LINE connector into the corresponding port on the Smart 
Connector. 
  
LOAD Connector 
The LOAD Connector accepts 18 AWG copper conductors, solid or stranded (16 strands 
or less). 
Use only one conductor per port and ensure that no copper is exposed on any of the 
wires after installation. 
1.
 Strip the wires to 3/8”. 
2.
 Grip the LOAD hot wire and firmly push conductor into the port marked with the black stripe.  
See Fig. 2. 
3.
 Grip the LOAD neutral wire and firmly push conductor into the unmarked port.  See Fig. 2. 
4.
 After LOAD wire installation, the load can safely be disconnected and re-connected without 
re-installing the wires.  To disconnect the load, firmly grip the LOAD connector and pull to 
separate it from the main body of the Smart Connector.  To re-connect, simply push the 
LOAD connector into the corresponding port on the Smart Connector. 
 
DIM Connector 
The DIM Connector accepts 18 AWG copper conductors, solid or stranded (16 strands 
or less). 
Use only one conductor per port and ensure that no copper is exposed on any of the 
wires after installation. 
1.
 Strip wires to 3/8”. 
2.
 Grip positive/(+)/purple DIM conductor and firmly push into the port marked “1”.  See Fig. 3. 
3.
 Grip negative/(-)/gray DIM conductor and firmly push into the port marked “2”.  See Fig. 3. 
4.
 After DIM wire installation, the DIM connector can safely be disconnected and re-connected 
without re-installing the wires.  To disconnect the DIM connector, firmly grip the DIM 
connector and pull to separate it from the main body of the Smart Connector.  To re-
connect, simply push the DIM connector into the corresponding port on the Smart    