Cinch Systems Inc RF-CHW-ITI-S 사용자 설명서
Specifications:
Input Voltage: 16.0VDC plug-in transformer
Backup Battery: 12VDC 5Ah max (optional)
Dimensions: 5.5” X 3.5”
Operating Temperature: 32 to 122F (0 to 50C)
Humidity: 95% RH Max
EOL Supervision: 1K to 10K Ohm
Input Zones: 16 (if used must have EOL resistor)
Zone Type—N/O or N/C compatible
Auxiliary Voltage Output: 12VDC @ 500mA
Cinch Stick Port: Field upgradable firmware
Tamper Zone: Separate zone input for tamper
Relay Contact—60VDC/1A Max, used to drive siren
or other device
or other device
Notes:
Used zones must have an EOL installed
If a backup battery is installed, the mod-
ule must be enrolled into the Qolsys
panel
panel
Make sure when installed the antenna is
free of all metal obstructions
Module Switches:
EOL Learn - used to calibrate EOL resistors and enter
program mode
Memory Reset - clears memory of module
program mode
Memory Reset - clears memory of module
Module LED’s
Processor - flashes during normal operation
RF Xmit - flashes when an RF transmission is sent
EOL Cal: On - calibration required, Off - calibration
complete
Zones: Flash twice when ready to enroll, On - when
enrolled in programming and when tripped, Off -
when zone in normal condition
RF Xmit - flashes when an RF transmission is sent
EOL Cal: On - calibration required, Off - calibration
complete
Zones: Flash twice when ready to enroll, On - when
enrolled in programming and when tripped, Off -
when zone in normal condition
Metal Enclosure
Plastic Enclosure
IC: 11817A-RFCHWITIS