)  Test sample placed in the cold-compartment for 2 hours, then placed the samples into a 
heat-compartment  for  2  hours;  repeated  in  turn  the  sample  placed  in  the 
cold-compartment and the heat-compartment for 2 hours each.    After test time-up to 48 
hours, the test sample has been relocated in a room temperature environment. 
 
 
 
   
After all the end of the test, test samples must pass the following test. 
1.   Trip switch position measurement and function measurement. 
2.   Keys measure - pressing a key with your finger on the middle and edges, check keys. 
3.   Plastic deformation of the keyboard check. 
4.   The contact-resistance of keys must less than 500Ω. 
5.   Check the key letter printing. 
 
5
  Vibration Test 
  Test Environments     
22℃    75%(RH) 
  Package  
 
 
 
20pcs/carton 
  Sweep Frequency     
10-55-10Hz/minutes 
  Amplitude of vibration  
76 cm 
  Orientation Vibration   
Each of X, Y, Z direction vibration tests for 1 hour