Innokas Yhtyma Oy VC150 사용자 설명서
11-2
VC150 Vital Signs Monitor
KO00065K
Welch Allyn temperature: Description
Description
You can measure oral, axillary or rectal temperatures with the Welch Allyn
SureTemp
SureTemp
®
Plus temperature parameter option. This parameter draws data
from an electronic thermometer with a temperature-sensing device known as a
thermistor at the tip of the probe. When the tip of the probe is brought in contact
with surrounding tissue, the electrical resistance is measured, the algorithm
calculates and displays the patient's temperature. The probe requires a probe
cover and should never be used without one.
thermistor at the tip of the probe. When the tip of the probe is brought in contact
with surrounding tissue, the electrical resistance is measured, the algorithm
calculates and displays the patient's temperature. The probe requires a probe
cover and should never be used without one.
The temperature is displayed on the upper right
corner of the monitor display. The temperature area
displays the temperature in degrees Celsius (° C) or
Fahrenheit (° F), time elapsed since last measurement
and measurement site. The Welch Allyn SureTemp
corner of the monitor display. The temperature area
displays the temperature in degrees Celsius (° C) or
Fahrenheit (° F), time elapsed since last measurement
and measurement site. The Welch Allyn SureTemp
®
Plus can operate in 2 different modes: predictive and
monitor.
monitor.
NOTES
A monitor with the Welch Allyn temperature technology configuration
setting cannot perform Exergen temperature measurements and vice versa.
setting cannot perform Exergen temperature measurements and vice versa.
The thermometer case, connectors, and probe are not waterproof. Do not
immerse or drip fluids on these items. Should this occur, dry the device with
warm air. Check all operating functions for proper operation.
immerse or drip fluids on these items. Should this occur, dry the device with
warm air. Check all operating functions for proper operation.
The Welch Allyn SureTemp
®
Plus thermometer consists of high quality
precision parts. Protect it from severe impact and shock. If the thermometer
has been dropped or if you notice any signs of damage to the probe or
instrument, do not use the thermometer. Contact service personnel to
ensure proper operation prior to further use.
has been dropped or if you notice any signs of damage to the probe or
instrument, do not use the thermometer. Contact service personnel to
ensure proper operation prior to further use.
Safety
WARNINGS
To ensure patient safety and accurate Welch Allyn temperature
measurement, use only Welch Allyn accessories and supplies.
measurement, use only Welch Allyn accessories and supplies.
Do not take a patient’s temperature without using a Welch Allyn
disposable probe cover. Doing so can cause patient discomfort, patient
cross-contamination, and erroneous temperature readings. Use only
Welch Allyn temperature probe covers.
disposable probe cover. Doing so can cause patient discomfort, patient
cross-contamination, and erroneous temperature readings. Use only
Welch Allyn temperature probe covers.
Long-term continuous monitoring beyond three to five minutes is not
recommended in any mode.
recommended in any mode.
Do not take an axillary temperature through patient’s clothing. Direct
probe cover to skin contact is required.
probe cover to skin contact is required.
Do not reuse, or sterilize and reuse protective covers. Apply a new cover
before each use.
before each use.