Ever Sinline Pro 2200VA/2000W W/SLPRTO-002K20/00 사용자 설명서

제품 코드
W/SLPRTO-002K20/00
다운로드
페이지 4
3000VA/2800W
4000VA/3000W
~150 - 280V (~160 - 265V) ± 2%
45 - 55Hz  1Hz
± 
~172 - 280V (~184 - 265V) 
 
± 2%
<3 ms
sinus
~230V ± 5%
50Hz   1Hz
±
LC
0 ms
8 x IEC 320 C13
+ / +
RS 232, USB, 
SNMP/HTTP network adapter (optional)
PowerSoft Personal
sound and LED
o
+10 C - +35 C / 
o
o
o
0 C - +45 C
up to 1000m
line-interactive (VI)
Tower
SINLINE Pro 2200
SINLINE Pro 3000  SINLINE Pro 4000
2200VA/2000W
380 x 170 x 600
2200, 3000, 4000, 5000
SINLINE Pro
SINLINE Pro 5000
5000VA/3250W
2 x 4 x VRLA 12V 9Ah
<3h
65kg
Circuit breaker
4 x 4 x VRLA 12V 9Ah
<10h
65kg
380 x 170 x 600
Electronic
Electronic
1) For normal operation of the battery back-up the load connected to its output should not exceed 80% of value indicated in the table. Reserve power is essential to ensure continuous operation of 
connected devices in case of momentary rushes in load current.
2) User may modify the threshold voltage value within the range provided. Default setting is provided in parentheses.
3) After discharging the UPS with 0.8 Pmax power – charging the battery to 90% capacity.
4) Continued exposure of the battery back-up to the ambient temperature exceeding +25°C will shorten the life of batteries.
5) If the altitude above sea level increases beyond the provided limit the permitted load power of the batter back-up decreases.
6) The acoustic signal may be turned off in the software.
MODEL
20 - 80% / 20 - 95% 
(without condensation)
same as input 
Noise filter RFI-EMI / varistor damper
Rooms with low level of pollution
Support time 
(100/80/50% Pmax)
Accumulator 
capacity
3)
UPS charging time 
UPS
UPS + 
battery module
UPS
Battery module
UPS
UPS + 
battery module
UPS
Battery module
UPS
Battery module
W
a
rn
in
g
T
h
e
 m
a
n
u
fa
c
tu
re
re
s
e
rv
e
s
 t
h
e
 r
ig
h
to
 c
h
a
n
g
e
 t
h
e
 a
b
o
v
e
m
e
n
ti
o
n
e
d
 p
a
ra
m
e
te
rs
 w
it
h
o
u
n
o
ti
c
e
.
Output power (apparent/active)
1)
 
Input voltage 
2)
Range of output voltage 
2)
Shape of output voltage
BACK-UP (BATTERY) OPERATION MODE
Output voltage
Shape of output voltage
Switching thresholds: UPS – mains 
2)
Filtering of output voltage
Shorting safeguard
Frequency of output voltage
Frequency of input voltage
MAINS OPERATION MODE
 
Switching thresholds: mains - UPS
2)
Time to switch to UPS
Overload protection
Filtering of output voltage
Technology
Case type
Switching time: UPS – mains
ENVIRONMENTAL PARAMETERS
Software
Number and type of outlet sockets
Telephone line / LAN filter
Communication interface
Signalling 
6)
Working environment
 
Operating / storage temperature 
4
)
 
Altitude above sea level
 
5
)
Relative humidity for operation / 
storage
EQUIPMENT
Overcurrent protection
MECHANICAL PARAMETERS
Dimensions in [mm] 
(h x w x d)
Weight
 ~150 - 170V
 / ~255 - 280V(
 
 
(~160V)
~265V) ± 2%
 ~155 - 170V
 / ~250 - 275V(
 
 
(~165V)
~260V) ± 2%
8/11,5/28 min
5/7/14 min
5,5/7,5/16 min
4,5/6,5/12 min
60/65/130 min
34/39/88 min
30/36/80 min
28/32/75 min