7. DEVICE   
 
7.1.  GENERAL 
 
 
 
1)  DISPLAY : Please decide output video resolution   
 It can be set to the correct video resolution on the monitor. 
[1920*1080P (default) 800*600  1024*768  1280*720  1280*1024     
 1600*1200  1680*1050  1920*1080I] 
 HDMI AUTO   
Automatically detects and sets the HDMI resolution on the monitor connected to the 
NVR.    It  might  display  “no  video”  if  a  VGA  monitor  is  not  able  to  support  high 
resolution.
 
  <NOTE>
In order to connect HDMI and VGA output to use both monitors, please set up 
as the lowest resolution without selecting HDMI AUTO.   
2)  Keypad Model: Select Joystick Controller and Baud Rate. 
3)  Extend Device: Select a model of POS/ATM.   
4)  PTZ Event: BHA-WC100 Model does not support this feature. 
5)  Alarm Out: DURATON [OFF,1SEC ~ 5 SEC]: Select Alarm duration. 
6)  IP CAM SET UP :   
After  click                          in  the  menu,  all  IP  cameras  which  are  connected  in  LAN 
network will be listed in the IP CAM Discovery menu.