Invenco Group Ltd G6OPT 사용자 설명서

다운로드
페이지 35
 
 
DCV-00001 Rev 05 S2 G6 OPT Installation Guide 
 
Page 24 
 
7 Removal & Reinstallation 
If the G6 OPT needs to be removed from its installation, please follow these steps: 
Step 
Description 
1. 
Ensure the terminal is not being used by a customer. 
2. 
Open the pump/pedestal door. 
Reverse-feed the paper to extract it from the printer.  
Remove the paper roll from the terminal. 
Switch off the mains power to the power supply. 
Carefully cut the cable ties holding the cables to the G6 OPT. Any other 
cable ties should be left in place. 
Unplug the LAN cable and the low-voltage power cable from the G6 OPT. 
Remove the Ground wire. 
7. 
Loosen and remove the screws holding the G6 OPT to the door. There 
will be either - 
a. 
12 screws around the outside of the rear plastics if the terminal was 
installed new, or 
b. 
4 screws into a pair of adaptor brackets if it was a retrofit. The 
brackets can remain in place unless they cause interference, or if 
you need to replace them as well. 
8. 
There is a soft foam gasket that seals the G6 OPT to the outside face of 
the door, and over time this is likely to stick to the door.  
Use gentle hand pressure to push the G6 OPT off the door, while holding 
the terminal on the outside to prevent it falling. 
Place the G6 OPT into suitable packaging for transport or perform the 
necessary maintenance. 
10. 
If the sealing gasket was stuck to the door, clean off any pieces of gasket 
material with a soft scraper, being careful not to damage the door surface.