G7OPT Integrator Manual, DWI-00175 S1 R15
suspend normal operation of the module and of the system as a whole – in particular it will temporarily
prevent any financial transactions.)
The battery compartment is enclosed within the UPC’s plastic housing. It is accessed from the rear of
the module, by undoing a captive Philips #2 screw then removing the lid of the compartment. The battery
is secured within the compartment by a Velcro strip. After removing the compartment lid, carefully
“unstick” the strip, disconnect the battery and remove it.
The battery connector is keyed; it cannot be plugged in with incorrect polarity. Fit a replacement battery,
plug in its connector and resecure the compartment lid. Check that no connections to the G7UPC have
been displaced then close and secure the system cabinet.
Follow the instructions under §3 Tampers to clear the removal-tampered state and restore the module
and overall system to normal operation.
Ensure that details of the battery change are recorded correctly.