CREATOR TECH CO. LTD CRT-603 사용자 설명서
SPECIFICATION
Model No.
CRT-603-DB1
Date
2012/11/24
User Manual
File Ver.
1.0
Page
41/48
4.2.20
Read Vendor MFG P/F
Read data of Vendor MFG P/F from EEPROM.
Command format:
Command format:
Command
Class
INS P1 P2 Lc
Read Vendor MFG P/F
68
92
E2
07
length
Parameter Description:
Length: length of Vendor MFG P/F, Range:1~4
Return format:
Data Out
Data (1-4byte)+ SW1 SW2
Data (1-4byte)+ SW1 SW2
Data: data of Vendor MFG P/F
SW1 SW2 STATUS CODE:
SW1 SW2 STATUS CODE:
SW1
SW2
Meaning
Success 90
00
Command
execution successfully
Fail
63
00
Command execution failed
67 00 Wrong
length
68
00
Class byte is not correct
69
00
Wrong data parameter
6A 81 Function
not
supported
6B 00 Wrong
parameter
P1-P2
Example:
Read data of Vendor MFG P/F, 68 92 E2 07 04
The corresponding command used of APDU channel transmission as follows
Command
Class INS P1 P2 Le Data
Read
Vendor
MFG
P/F FF
69
44
42
5
68 92 E2 07 XX
Parameter description, Return format, SW1 SW2 status code as above