6 – Attach signal wiring.
RS232 – 3 wires are required to connect the RS232 port to another device such as a 
PC with a 9 pin D connector. The TX terminal on the well watch connects to pin 2 of the 
D connector, RX to pin 3, and GND to pin 5.
RS485 - 3 wires are required to connect the RS485 port to a Modbus bus. The A line, 
the B line, and the shield to the GND terminal. 
0-5v Analog out – 2 wires are required, the Analog Out terminal is the positive and 
GND is the negative. This terminal can source up to 15ma.
4-20ma out – External power up to 36 volts is required to power the current loop. This 
is frequently provided by the remote monitoring equipment and must be isolated from 
the Well Watch power.  The positive wire connects to the + terminal, and negative to 
the – terminal.
Alarm – 2 wires are required, the Alarm terminal is positive and the GND terminal is 
negative. This output can source up to 5 volts at 15ma.
7 – Route the wires opposite the hinge and close the unit so that the wires come 
through the opening.
8 – Protect unit to avoid damage and direct weather exposure.
OPERATION
POWER ON:  Apply power to start the Well Watch.  The probe will pulsate and the LCD 
screen will display a product information screen for a few seconds then go to the 
default DISPLAY mode screen. The depth is displayed on the top line once the unit 
adjusts to the well and calculates a stable reading. While the unit adjusts to the well the 
display will read “DEPTH SEARCHING.” 
Note:  If error conditions exist, line two of the display will be replaced by an alternating 
error message. See the ERROR CODES section for details.
  Eno Scientific  Well Watch 660DL