UHS Pty Ltd UM-ZW 사용자 설명서

다운로드
페이지 4
UM-ZW Installer Manual RevC.docx 
 
Page 3 
3.  Select Z-Wave Add\Remove in the drop 
down menu.  
 
 
4.  Click Add. 
 
5.  Initiate LINK or ADD mode on Z-Wave 
device. See your Z-Wave device’s manual 
for instructions. 
 
6.  Note: If a Z-Wave device has been added 
before or to another system, you must first 
remove it before adding it to this system. 
To do this, click Remove, then activate 
LINK or REMOVE mode on the device. 
 
7.  Click Rooms. 
 
8.  Check you can see the device you just 
added. Click a button such as ON or OFF 
to verify you can control the device. 
 
Automation Scenes 
Once Z-Wave devices have been added, they 
can be switched on and off in response to 
system events. Refer to the xGen Installation 
& Programming Guide
 for instructions on 
creating automation scenes. 
Supported Z-Wave Devices 
Type 
Description 
Binary On/Off 
Switch 
Non-secure mode, for controlling appliances 
such as lamps, TV, garage door opener, and 
other devices that connect to a power point. 
Dimmer 
Non-secure mode, for controlling brightness 
level of dimmable lights. 
Door Locks 
Secure mode only, supports locking, 
unlocking, PIN code share, and status. 
Thermostat 
Non-secure mode, control temperature set 
points, on, off, fan, mode, and temperature 
reading. 
Note on Range 
Z-Wave devices form a wireless mesh network 
where each device acts as a short-range 
repeater. 
 
Battery powered devices are not recommended 
for use as repeaters due to limited battery life. 
To extend the range of your Z-Wave network, 
install mains powered Z-Wave devices such as 
an On/Off power point. 
 
For example, when adding a door lock, ensure 
there is at least one mains powered Z-Wave 
device between the lock and the UM-ZW Z-
Wave Module to provide more reliable 
wireless coverage. 
Specifications 
•  Compatibility: xGen control panels 
•  Frequency: 908.42 MHz in US, 868.42 
MHz in EMEA, 921.42 MHz in ANZ 
•  Required Power: 12.0 VDC (provided by 
panel) 
•  Current Draw: 80 mA maximum 
•  Operating Temperature Range 0° to 49°C 
(32° to 120°F) 
•  Storage Temperature: -34° to 60°C (-30° to 
120°F) 
•  Maximum Humidity: 90% relative 
humidity non-condensing 
•  Dimensions: 155 mm H x 95 mm W x 68 
mm D 
 
Manufacturer 
Placed on the market by: 
UTC Fire & Security Americas Corporation, Inc. 
3211 Progress Drive, Lincolnton, NC, 28092, USA 
 
This equipment has been tested and found to comply with the limits for a 
Class B digital device, pursuant to part 15 of the FCC Rules. These limits 
are designed to provide reasonable protection against harmful interference 
when the equipment is operated in a commercial environment. This 
equipment generates, uses, and can radiate radio frequency energy and, if 
not installed and used in accordance with the instruction manual, may cause 
harmful interference to radio communications.