UHS Pty Ltd ZW-6400H 사용자 설명서

다운로드
페이지 2
2 / 2 
 
P/N 230910 • REV B • ISS 071217 
Figure 3: Installing antenna(s) 
 
2.  For applications where the hub is permanently mounted 
on a wall, create a hole to allow the antenna to drop down 
the wall. 
3.  For applications where the hub is mounted on a desktop 
stand, secure the antenna in a place that cannot be easily 
moved by using the included adhesive strip. 
Note: 
Be sure to keep hub and cellular antennas away from 
electrical devices such as appliances, routers, cables boxes, 
as well as mirrors to optimize signal strength. 
Commissioning the cellular module 
To commission the module: 
1.  Once the cellular module is installed in the hub, it will 
automatically start to try and find a cellular network.  
2.  When provisioning the system on the UltraSync Portal, 
remember to select a Service Grade that includes Cellular. 
Specifications 
 
Voltage 
5VDC (provided by panel) 
Current 
40 mA min / 750mA max at 9 V 
External connector 
Two MMCX 
Dimensions (W × H × 
D) 
97 x 31.5 x 20mm 
Storage temperature 
-34° to 60°C (-30° to 120°F) 
Weight 
190 g 
Operating environment
 
Temperature
 
Relative humidity 
 
0° to 49°C (32° to 120°F) 
maximum 90% noncondensing 
 
Regulatory information 
 
Manufacturer 
Placed on the market by: 
UTC Fire & Security Americas Corporation, Inc. 
3211 Progress Drive, Lincolnton, NC, 28092, 
USA. 
US/C compliance 
FCCID: N7NHL7588 
 
IC: 2417C-HL7588   
 
This equipment has been tested and found to comply with the limits 
for a Class B digital device, pursuant to part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a commercial 
environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with 
the instruction manual, may cause harmful interference to radio 
communications. 
If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:  
• Reorient or relocate the receiving antenna.  
• Increase the separation between the equipment and receiver.  
• Connect the equipment into an outlet on a circuit different from that    
   to which the receiver is connected.  
• Consult the dealer or an experienced radio/TV technician for help. 
This class B digital apparatus complies with Canadian ICES-3B. 
Cet appareil numérique de la classe B est conforme à la norme 
NMB-003 du Canada. 
 
Caution: Any changes or modifications not expressly approved by the 
party responsible for compliance to this equipment would void the 
user’s authority to operate this device. 
 
This Device complies with FCC & ISED radiation exposure limits. 
 
This device complies with Industry Canada’s licence-exempt RSSs. 
Operation is subject to the following two conditions: 
(1) This device may not cause interference; and 
(2) This device must accept any interference, including interference 
that may cause undesired operation of the device. 
 
Le présent appareil est conforme aux CNR d’Industrie Canada 
applicables aux appareils radio exempts de licence. L’exploitation est 
autorisée aux deux conditions suivantes : 
1) l’appareil ne doit pas produire de brouillage; 
2) l’utilisateur de l’appareil doit accepter tout brouillage 
radioélectrique subi, même si le brouillage est susceptible d’en 
compromettre le fonctionnement. 
 
Contact information 
For contact information, go to 
www.utcfireandsecurity.com
 or 
www.interlogix.com
 
Customer support (US) 
For customer support, contact 
 Interlogix Technical Support  
Tel +1 855 286 8889 (Option 2)  
techsupport@interlogix.com  
www.interlogix.com
 