Hangzhou Hikvision Digital Technology Co. Ltd. MP7608HN 사용자 설명서

다운로드
페이지 89
Mobile Network Video Recorder User Manual 
21 
 
 
Figure 2-18 Install Fuse for Two Types of Power Supply 
ACC
DC IN
+
-
Device
Automobile 
Battery
Automobile Power Switch
Automobile Power System
Wiring of Device
Point of Connection
Negative Pole
Positive Pole
 
Figure 2-19 Scheduled Shutdown 
2.7 Alarm Input/Output Connection 
2.7.1 Alarm Input Connection 
The device adopts the high/low-level electrical signals triggering (high level: 6 to 36 VDC; low 
level: 0 to 5 VDC) to realize alarm input. And in order to avoid error report caused by voltage 
fluctuation, no alarm will be triggered by voltage ranging of 5 to 6 VDC.   
Alarm 1
IO
Alarm 2
Alarm 3
Alarm 4
1
2
15
16
  
Figure 2-20 Alarm Input Connection