Mobile Network Video Recorder User Manual 
49 
Step 1 Go to Menu > Other Settings > Alarm In
 
Figure 8-8 Alarm Input Settings 
Step 2 Click Set of Triggered Camera to select the alarm triggered recording channel.   
Step 3 Click OK
Step 4 Enter the record settings interface to set alarm triggered recording schedule. Refer to 
8.2.5 Configure Schedule for record settings. Recording type must be alarm, motion | 
alarm, or motion & alarm. 
8.2.4 Configure Alarm Terminal 
Before you start: 
  Install an alarm terminal. For details, refer to alarm terminal user manual. 
  The RS-232 serial port should be used in the way of transparent channel and the baud 
rate should be set as 9600. 
Step 1 Go to Menu > Other Settings > Alarm Terminal
 
Figure 8-9 Alarm Terminal 
Step 2 Check Enable Alarm Terminal
Step 3 Edit Terminal Name