Alinket Electronic Technology Co. Ltd. ALXCOMBO 사용자 설명서

다운로드
페이지 28
 
ALXC2X  USER  MANUAL 
Alinket Proprietary & Confidential Information       
E-mail
 Website
   
14 
3.
 Configuration with ACM 
The  host  control  interface  are  used  for  transferring  the  Alinket  Controller  Message  (ACM),  Flow 
Control signal and Power Save signal between Host Board and ALX module. 
3.1 Hardware Reference Model 
The Host Control Interfaces are used to connect Host Board and ALX Controller. It includes ACM Bus, 
Flow Control Bus (Hardware Flow Control mode) and Power Save Bus (Power Save feature enabled). 
 
Figure 7 Hardware Reference Model 
3.2 ACM Bus 
ACM  Bus  is the  interface  for  exchanging  the message  between  Host Board  and ALX Controller.  It 
could be the UART interface and SPI interface. 
The messages are the control commands from Host Board, the response of commands from ALX 
Controller and alarm event from ALX Controller. 
Input and output are UART interface with TTL level signals. 
 
Figure 8 Connection Diagram