LED Surface Mounted Luminaire 
Products model: 
 
TOPA2400-LED-HUV-X-sensor, TOPA2400-LED-HUV-X-sensor-W 
 
Key Features 
 Drive Mode: Constant Current. 
 Technology: Active PFC Single-Stage Switch Mode. 
 Input Voltage: 347 to 480 Vac. 
 Output Power: 75 Watt Max. 
 Dimming: Smooth & Continuous Dimming from 10% to 100%. 
LEDs turn on to any dimmed level without going to full brightness. 
Constant Current Reduction (CCR) dimming methods. 
0-10V: 2-wire Analog / PWM Control Dimming. 
 Output Voltage: 4 Vdc to 130 Vdc. 
 Output Current: 300 mA to 3330 mA. 
 Efficiency: Up to 89%. 
 Warranty: 5 years. 
Microwave Frequency:5.8GHz+/-75MHz 
 
Special Features 
 Continuous, dimming from 10% to 100%. 
 Safety isolation between primary and secondary. 
 A rated lifetime of 50,000 hours @ Tc = 83 
°C. 
 Safety: UL8750, UL1310 Class 2, CSA22.2. 
 Inrush Current Limiting Circuitry: AC Power Line: line to line 3 kV, 
eliminates circuit breaker tripping, switch arcing and relay failure. 
 Plastic shell, Used with silicone potting. Meet the RoHs directive. 
 IP65, NEMA4 compliant for Dry, Damp. 
 100% performance tested with CHROMA 8000 system at YG factory. 
■ 100% burned in with program-control test system at YG factory, at 50 degrees ambient 
temperature. 
 
Safety instruction 
1.Electrical works have to be done by technical persons. 
2.Disconnect the lamp from the power supply and let the lamp cool down before replacing the 
luminaire. 
3.Never touch the luminaire when the power is on. 
4.In case of damages, disconnect the lamp from the power supply. Do not try to  repair the lamp on 
your own. Repair has to be done by technical persons or customer service. 
Installation 
 1.Drill the fitting holes at the place of installation (wall/ ceiling), make sure, that no 
  cables or other lines are passing in place of drilling. 
  2.Put the screws in the holes and fix the lamp to the mounting place. 
  3. Insert the power cable (Type SJTW, 18AWG, min 80℃) connected to the 
  connector,  through the bushing in the opening . (By slightly pulling, the position  
  of the washer can be  optimised) 
   4. When Connect the connector, Pay attention to the correct polarity