Radio Solutions Inc SB800M2A 사용자 설명서
© 2016 Radio Solutions, Inc. Norwell, MA - USA
6
Electrical Specifications:
Frequency Range
806-815MHz UL / 851-860MHz DL
Maximum Gain (adjustable)
92dB (Typ)
Gain Adjustment, 1 dB steps.
50dB to 92dB = 42dB total adjustment
range
range
Maximum Composite Output Power
(i.e. single carrier)
(i.e. single carrier)
30dBm
Power Limiter Adjustment (1dB increments) 30dBm to 16dBm
Impedance
Impedance
50 Ohm
Maximum RF Signal Input Level for FCC
spurious limits compliance
spurious limits compliance
-20dBm
Absolute Maximum Input RF Signal Level
0dBm continuous, +10dBm peak
Noise Figure
<6.5dB typ. 8dB max.
Alarms:
Two Form C relays for each of the alarms:
AC Power Status, Charger Status, Low
Battery Capacity, Low Battery Voltage, BDA
Trouble, Antenna Trouble and Aux Alarm.
Second relay contact set provided for a LED
annunciator panel.
AC Power Status, Charger Status, Low
Battery Capacity, Low Battery Voltage, BDA
Trouble, Antenna Trouble and Aux Alarm.
Second relay contact set provided for a LED
annunciator panel.
Alarm Logging:
Standard SD Card up to 16GB. Mini SD with
adaptor. Real-time clock time stamp
included.
adaptor. Real-time clock time stamp
included.
AC Power Supply
Two independent power supplies with 110-
240VAC/2.1A or 277VAC/0.8A 50/60Hz
each.
240VAC/2.1A or 277VAC/0.8A 50/60Hz
each.
Power Supply Efficiency
93% (Typ.)
DC Power Supply
Supports either 2x75Ah 12V AGM Sealed
L.A. Batteries in series for DC UPS Backup
or an external 28VDC Supply. Max. Current
Draw: 2.3A @ 28VDC
L.A. Batteries in series for DC UPS Backup
or an external 28VDC Supply. Max. Current
Draw: 2.3A @ 28VDC
Run Time with standard 2x75Ah Battery
Backup
Backup
>25-30 Hours under full load
Battery Charging with the Built-in
Charger**
Charger**
Charging Current Limited to 5A max. Float
voltage: 27.4V
voltage: 27.4V
Operating Temperature Range
-30°C to +65°C
Recommended Ambient Temperature***
-20°C to +35°C (-4°F to +95°F)
** Only use approved lead-acid batteries. Contact RSI for list of approved batteries.
*** Extended ambient temperatures and outdoor applications may require specialized
enclosures. Please inquire with your specific requirements.
enclosures. Please inquire with your specific requirements.
*** Operating the device outside the recommended ambient temperature range may void
the warranty.
the warranty.