RuiXingHengFang Network Co. Ltd. 76052 사용자 설명서

다운로드
페이지 44
V2.6 2015-12-03
www.risinghf.com
LoRaWAN Module RHF76-052 User Manual
RisingHF
5
Figure 3- 2 RHF76-052 AN Reference Design (FW upgrade with USB)
Hardware design description:
1) VCC operation range: +1.8V to +3.6V
2) Pin22 and Pin 23 of the Modem would be used as UART port, please connect to Host MCU. Pin22
should be connected to RXD of Host MCU, and Pin23 should be connected to TXD of Host MCU.
3) For RHF76-52 AM: Pin4 and Pin5 of the Modem would be used as FW upgrade port based on UART
connection. Pin4 should be connected to RXD of Host, and Pin5 should be connected to TXD of Host.
For RHF76-052 AN: Pin10 and Pin11 of the Modem would be used as FW upgrade port based on
USB CDC connection. Pin10 should be connected to USB_DM, and Pin11 should be connected to
USB_DP.
4) Pin14 (GPIO_PA15) would be used to enable the DFU mode for FW upgrade. Please connect it to a
toggle switch to achieve DFU enable function via a hardware way.
Note: Customer could also use a SW way with AT command to access into DFU mode.
5) Pin16 would be used to show LoRaWAN processing status. Please connect this pin to a LED if need.
This LED would blink when transmit or receive a message in LoRaWAN mode.