iStarUSA CP-02040 사용자 설명서
1. Input Characteristics:
1.1 Input Voltage Range --- 100~240Vac, full range with active power factor 90% min
1.2 Input Frequency Range --- 47Hz to 63Hz.
1.3 Input Ac Current ( Max ) --- 8.0A max, full load.
1.4 Inrush Current --- At 132Vac / 264Vac, full load condition,
no damage occur, input fuse shall not blow.
no damage occur, input fuse shall not blow.
1.5 Efficiency --- 70% min, at nominal line input full load.
1.6 Input Leakage Current --- Leakage current from line to ground
will be less 10mA rms, measurement will be made at 240Vac/60Hz.
will be less 10mA rms, measurement will be made at 240Vac/60Hz.
2. Output Characteristics:
2.1 Static Output Characteristics.
Output
Voltage
Load Range
Min. Max.
Regulation
Min. Max.
Ripple Max
mV P-P
Ripple & Noise
Max. mV P-P
1.
+3.3 V
0.5 A
20.0 A
- 5 %
+ 5 %
50 mV
100 mV
2.
+5.0 V
0.3 A
30.0 A
- 5 %
+ 5 %
50 mV
100 mV
3.
+12.0 V
1.0A
30.0 A
- 5 %
+ 5 %
100 mV
150 mV
4.
-5.0 V
0.0 A
0.5 A
- 10 %
+ 10 %
150 mV
200 mV
5.
-12.0 V
0.0 A
0.5A
- 10 %
+ 10 %
150 mV
200 mV
6. SB +5.0 V
0.0 A
3.0 A
- 5 %
+ 5 %
100 mV
100 mV
Note:
1. Noise Test --- Noise bandwidth is from Dc to 20MHz.
2. Ripple frequencies greater than 1 MHz shall be attenuated by the
measurement system.
3. Add 0.1uF / 10uF capacitor at output connector terminals for ripple &
noise measurements.
4. Combined total power from +3.3V and +5V rails shall not exceed 150W.
5. The total output power shall not exceed 400W.
2.2 Dynamic Output Characteristics:
2.2.1 Initial Delay Time --- NONE.
2.2.2 Rise Time --- 50 mS max, at nominal line full load.