4. Service Output 
Test conditions: -- temperature at 20
±2
℃,
 
                            -- test to be carried out within 60 days after production data. 
Discharge Conditions 
Average Minimum Discharge Time 
Standard 
Discharge 
load (Ω) 
Discharge 
Time 
E.P.V. 
(V) 
New Battery 
 
After 12 moths 
at room temp 
IEC 
43 
4h/d 
0.9 
90 h 
81 h 
IEC 
10 
1h/d 
0.9 
18 h 
16 h 
IEC 
 
3.9 
1h/d 
0.8 
6.5 h 
5.8 h 
IEC 
24 
15s/min, 8h/d 
0.9 
45 h 
41 h 
IEC 
Drain 
1000mA 
10s/min, 1h/d 
0.9 
300 cycles 
270 cycles 
Satisfaction Standard: 
    1) 9 pieces of battery will be tested for each discharging standard; 
    2) The result of the average discharging time from each discharging standard shall be equal to or 
        more than the average minimum time requirement; no more than one battery has a service 
        output less than 80% of the specified requirement. 
    3) One re-test is allowed to confirm the previous result. 
5. Electrolyte Leakage Proof Characteristics 
Item 
Condition 
Period 
Requirement 
Acceptance 
Standard 
Over-discharge 
Characteristics 
10Ω continuous 
discharge  at  temperature 
20±2
℃;  relative  humidity: 
60
±15% RH 
48 
hours 
N = 9: 
Ac = 0; 
Re = 1 
Storage 
Characteristics 
Storage at temperature 
60±2
℃;  relative  humidity 
below 90
% RH 
20 
days 
There shall be no 
deformation  exceeding 
the specified 
dimensions, nor 
leakage  recognized  by 
human eye. 
N = 30: 
Ac = 1; 
Re = 2 
Alkaline Battery                                                          LR6/AA
 
6. Safety Characteristics
 
Item 
Condition 
Period 
Requirement 
Acceptance Standard 
Short-circuit 
Characteristics 
At temperature 
20±2
 
24 hours 
No explosion 
allowed 
N = 5: 
Ac = 0; Re = 1 
Incorrect 
Installation 
4 pcs in series with 1 
pc reverse polarized 
(IEC60086-5) 
24 hrs or till 
battery casing 
temp reaches 
room temp 
No explosion 
allowed. 
N = 4 x 5: 
Ac = 0; Re = 1