HQ -ALK-AAA-03 HQ-ALK-AAA-03 사용자 설명서
제품 코드
HQ-ALK-AAA-03
Page 3 of 5
-- test to be carried out within 60 days after production data.
Satisfaction Standard:
1) 9 pieces of battery will be tested for each discharging standard;
2) The result of the average discharging time from each discharging standard shall be equal to or
more than the average minimum time requirement; no more than one battery has a service
output less than 80% of the specified requirement.
3) One re-test is allowed to confirm the previous result.
5. Electrolyte Leakage Proof Characteristics
Item
Condition
Period
Requirement
Acceptance
Standard
Over-discharge
Characteristics
20Ω continuous
discharge at temperature
20±2
℃; relative humidity:
60
±15% RH
48
hours
N = 9;
Ac = 0;
Re = 1
Storage
Characteristics
Storage at temperature
60±2
℃; relative humidity
below 90
% RH
20
days
There shall be no
deformation exceeding
the specified
dimensions, nor
leakage recognized by
human eye.
N = 30;
Ac = 1;
Re = 2
Alkaline Battery LR03/AAA
6. Safety Characteristics
Item
Condition
Period
Requirement
Acceptance Standard
Short-circuit
Characteristics
At temperature 20±2
℃
24 hours
No explosion
allowed
N = 5:
Ac = 0; Re = 1
Incorrect
Installation
4 pcs in series with 1
pc reverse polarized
(IEC60086-5)
24 hrs or till
battery casing
temp reaches
room temp
No explosion
allowed.
N = 4 x 5:
Ac = 0; Re = 1
7. Marking
The following markings will be printed, stamped or impressed on the body of battery:
Discharge Condition
Average Minimum Discharge Time
Standard
Discharge
Load
Discharge
Time
E.P.V.
(V)
New Battery
After 12 mths,
at room temp.
IEC
75Ω
4 h/d
0.9
70 h
63 h
IEC
10Ω
1 h/d
0.9
7 h
6.3 h
IEC
5.1Ω
4 m/h, 8 h/d
0.9
200min
180min
IEC
24Ω
15s/min,8h/d
1.0
20 h
18 h
IEC
Drain
600mA
10s/min,1h/d
0.9
250 cycles
225 cycles
Daily-max
20Ω
24h/d
0.9
16.5 h
14.8 h