Operating flexibility
Different operating modes that can
be programmed according to on user
requirements and the load to be powered
have been introduced in order to reduce
energy consumption.
• On line: maximum load protection and
be programmed according to on user
requirements and the load to be powered
have been introduced in order to reduce
energy consumption.
• On line: maximum load protection and
output voltage waveform quality
• Economy Mode: the UPS uses line
interactive technology, with the load
powered by the mains, reducing
consumption and thus improving
efficiency (up to 98%).
powered by the mains, reducing
consumption and thus improving
efficiency (up to 98%).
• Smart Active Mode: the UPS automatically
selects on-line or line interactive
operation, depending on the quality of
the mains supply, checking the number,
frequency and type of disturbances
present.
operation, depending on the quality of
the mains supply, checking the number,
frequency and type of disturbances
present.
• Stand by Off (emergency): The UPS
supplies the load only when the mains
fails. The inverter begins working with a
progressive start-up sequence to prevent
inrush currents.
fails. The inverter begins working with a
progressive start-up sequence to prevent
inrush currents.
• Frequency converter operation (50 or 60
Hz).
Emergency function
This configuration ensures the operation of
emergency systems that must be supplied
in the event of a mains power failure, such
as emergency lighting, fire detection/
extinguishing systems and alarms. When the
mains power supply fails, the inverter begins
powering the loads with a progressive start-
up (Soft Start) in order to prevent overload.
Sentinel Pro is compliant for installation
in medium-voltage transformer rooms in
accordance with applicable legislation, for
the power supply with reserve charge of
medium-voltage coils.
emergency systems that must be supplied
in the event of a mains power failure, such
as emergency lighting, fire detection/
extinguishing systems and alarms. When the
mains power supply fails, the inverter begins
powering the loads with a progressive start-
up (Soft Start) in order to prevent overload.
Sentinel Pro is compliant for installation
in medium-voltage transformer rooms in
accordance with applicable legislation, for
the power supply with reserve charge of
medium-voltage coils.
Battery optimisation
The Sentinel Pro range has a deep discharge
protection device to optimise battery life.
Periodically the UPS carries out a battery
efficiency test (which can also be manually
activated); its wide input voltage tolerance
range helps to reduce battery usage and
maintain performance over time.
protection device to optimise battery life.
Periodically the UPS carries out a battery
efficiency test (which can also be manually
activated); its wide input voltage tolerance
range helps to reduce battery usage and
maintain performance over time.
Runtime expandability
Optional battery extension packs can be
connected to increase UPS runtime. In
addition the Sentinel Pro range includes
ER versions with no internal batteries and
more powerful battery chargers for longer
runtimes.
connected to increase UPS runtime. In
addition the Sentinel Pro range includes
ER versions with no internal batteries and
more powerful battery chargers for longer
runtimes.
Low noise level
Thanks to the use of high frequency
components and load-based fan speed
control, the noise produced by the UPS is
less than 40 dBA.
components and load-based fan speed
control, the noise produced by the UPS is
less than 40 dBA.
Features
• Filtered, stabilised and reliable voltage:
double conversion on-line technology
(VFI compliant with IEC 62040-3) with
filters for the suppression of atmospheric
disturbances.
(VFI compliant with IEC 62040-3) with
filters for the suppression of atmospheric
disturbances.
• High overload capability (up to 150%)
• Programmable Auto-restart when mains is
• Programmable Auto-restart when mains is
restored
• Battery start-up (cold start)
DEtAILS
OUTPUT SOCKETS
BATTERY EXPANSION
CONNECTOR
COMMUNICATIONS
SLOT
SERIAL
INTERFACE
USB PORT
INPUT SOCKET