Intel S1200BTLR DBS1200BTLR 사용자 설명서

제품 코드
DBS1200BTLR
다운로드
페이지 153
Intel® Server Board S1200BT TPS 
Connector/Header Locations and Pin-outs 
Revision 1.0 
   
Intel order number G13326-003 
95 
7.4.2 
Reset Button 
The platform supports a front control panel reset button. Pressing the reset button initiates a 
request forwarded by the Integrated BMC to the chipset. The BIOS does not affect the behavior 
of the reset button. 
7.4.3 
System Status Indicator LED 
The Intel
® 
Server Board S1200BTL has a system status indicator LED on the front panel. This 
indicator LED has specific states and corresponding interpretation as shown in the 
following table. 
Table 27. System Status LED Indicator States 
Color 
State 
Criticality 
Description 
Green 
Solid on 
Ok 
System booted and ready 
Green 
~1 Hz blink 
Degraded 
System degraded: 
Non-critical temperature threshold asserted. 
Non-critical voltage threshold asserted. 
Non-critical fan threshold asserted. 
Fan redundancy lost, sufficient system cooling maintained. This does 
not apply to non-redundant systems. 
Power supply predictive failure. 
Power supply redundancy lost. This does not apply to non-redundant 
systems. 
Correctable errors over a threshold of 10 and migrating to a spare 
DIMM (memory sparing). This indicates the user no longer has 
spared DIMMs indicating a redundancy lost condition. Corresponding 
DIMM LED should light up 4. 
Amber 
~1 Hz blink 
Non-critical 
Non-fatal alarm 
– system is likely to fail: 
CATERR asserted. 
Critical temperature threshold asserted. 
Critical voltage threshold asserted. 
Critical fan threshold asserted. 
VRD hot asserted. 
SMI Timeout asserted. 
Amber 
Solid on 
Critical, non-
recoverable 
Fatal alarm 
– system has failed or shutdown: 
Thermtrip asserted. 
Non-recoverable temperature threshold asserted. 
Non-recoverable voltage threshold asserted. 
Power fault/Power Control Failure. 
Fan redundancy lost, insufficient system cooling. This does not apply 
to non-redundant systems. 
Off 
N/A 
Not ready 
AC power off, if no degraded, non-critical, critical, or non-recoverable 
conditions exist. 
Notes: 
1.  The BIOS detects these conditions and sends a Set Fault Indication command to the Integrated BMC to provide 
the contribution to the system status LED.  
2.  Support for upper non-critical limit is not provided in the default SDR configuration. However, if a user does 
enable this threshold in the SDR, then the system status LED should behave as described
There is no precedence or lock-out mechanism for the control sources. When a new request 
arrives, all previous requests are terminated. For example, if the chassis ID LED is blinking and 
the chassis ID button is pressed, then the chassis ID LED changes to solid on. If the button is 
pressed again with no intervening commands, the chassis ID LED turns off.