Platform Management 
Intel® Server Board S1200BT TPS 
 
 
Revision 1.0 
Intel order number G13326-003 
42 
sensors on the installed memory DIMMs.
 
The Integrated Memory Controller (IMC) dynamically 
changes throttling levels to cap throttling based on memory and system thermal conditions as 
determined by the system and DIMM power and thermal parameters.
 
Support for CLTT on 
mixed-mode DIMM populations (i.e. some installed DIMMs have valid temp sensors and some 
do not) is not supported.
 
The Integrated BMC fan speed control functionality is related to the 
memory throttling mechanism used. 
The following terminology is used for the various memory throttling options: 
   Static Open Loop Thermal Throttling (Static-OLTT):
 
OLTT control registers are 
configured by BIOS MRC remain fixed after post. The system does not change any of 
the throttling control registers in the embedded memory controller during runtime.
  
 
   Static Closed Loop Thermal Throttling (Static-CLTT):
 
CLTT control registers are 
configured by BIOS MRC during POST. The memory throttling is run as a closed-loop 
system with the DIMM temperature sensors as the control input. Otherwise, the system 
does not change any of the throttling control registers in the embedded memory 
controller during runtime. 
4.3.2 
Fan Speed Control 
BIOS and BMC software work cooperatively to implement system thermal management 
support. During normal system operation, the BMC will retrieve information from the BIOS and 
monitor several platform thermal sensors to determine the required fan speeds. 
In order to provide the proper fan speed control for a given system configuration, the BMC must 
have the appropriate platform data programmed. Platform configuration data is programmed 
using the FRUSDR utility during the system integration process and by System BIOS during 
run time. 
4.3.2.1 
System Configuration Using the FRUSDR Utility 
The Field Replaceable Unit and Sensor Data Record Update Utility (FRUSDR utility) is a 
program used to write platform-specific configuration data to NVRAM on the server board. It 
allows the user to select which supported chassis (Intel
®
 or Non-Intel) and platform chassis 
configuration is used. Based on the input provided, the FRUSDR writes sensor data specific to 
the configuration to NVRAM for the BMC controller to read each time the system is powered on. 
4.4  Intel
®
 Intelligent Power Node Manager 
4.4.1 
Overview 
Power management deals with requirements to manage processor power consumption and 
manage power at the platform level to meet critical business needs.
 
Node Manager (NM) is a 
platform resident technology that enforces power capping and thermal-triggered power capping 
policies for the platform. These policies are applied by exploiting subsystem knobs (such as 
processor P and T states) that can be used to control power consumption.
 
NM enables data 
center power management by exposing an external interface to management software through 
which platform policies can be specified. It also implements specific data center power 
management usage models such as power limiting, and thermal monitoring.