AlcAtel-lucent
dAtA Sheet
technicAl SpeciFicAtiOnS
pOrt
OS6450-10l
OS6450-10
OS6450-p10l
OS6450-p10
RJ-45 10/100 ports
8
0
8
0
RJ-45 10/100/1000 ports
0
8
0
8
RJ-45/SFP 10/100/1000 combo ports
2
2
2
2
SFP uplink/stacking ports
2
2
2
2
PoE ports
0
0
8
8
Maximum units stackable*
2
2
2
2
Dimensions
Switch width
8.50 in. (21.5 cm)
8.50 in. (21.5 cm)
8.50 in. (21.5 cm)
8.50 in. (21.5 cm)
Switch height
1.73 in. (4.4 cm)
1.73 in. (4.4 cm)
1.73 in. (4.4 cm)
1.73 in. (4.4 cm)
Switch depth
11.5 in. (29.21 cm)
11.5 in. (29.21 cm)
11.5 in. (29.21 cm)
11.5 in. (29.21 cm)
Performance (FD/Aggregated)
Switch capacity (2GigE uplinks)
2.8/5.6 Gb/s
10/20 Gb/s
2.8/5.6 Gb/s
10/20 Gb/s
Switch capacity (4GigE uplinks)
4.8/9.6 Gb/s
12/24 Gb/s
4.8/9.6 Gb/s
12/24 Gb/s
Stacking capacity
10/20 Gb/s
10/20 Gb/s
10/20 Gb/s
10/20 Gb/s
Operating conditions
Operating temperature
0°C to +45°C
32°F to +113°F
32°F to +113°F
0°C to +45°C
32°F to +113°F
32°F to +113°F
0°C to +45°C
32°F to +113°F
32°F to +113°F
0°C to +45°C
32°F to +113°F
32°F to +113°F
Storage temperature
-40°C to +75°C
-40°F to +167°F
-40°F to +167°F
-40°C to +75°C
-40°F to +167°F
-40°F to +167°F
-40°C to +75°C
-40°F to +167°F
-40°F to +167°F
-40°C to +75°C
-40°F to +167°F
-40°F to +167°F
Humidity (operating and storage)
5% to 95%
5% to 95%
5% to 95%
5% to 95%
MTBF (hours)
695, 192
695, 192
499, 729
499, 729
Power supply efficiency
85.6%
85.6%
90.1%
90.1%
Fanless design
Yes
Yes
Yes
Yes
Acoustic (dB)
Silent
Silent
Silent
Silent
System power consumption (watts)**
~17 W
~17 W
~23.5 W
~23.5 W
Heat dissipation (Btu)
58
58
78
78
PoE power budget
N/A
N/A
120 W
120 W
PoE device heat dissipation (Btu)
N/A
N/A
409
409
* Stacking available in a future software release
** Power consumption measured under fully loaded traffic conditions
** Power consumption measured under fully loaded traffic conditions
indicators
System leds
• System (OK) (chassis HW/SW status)
• PWR (primary power supply status)
• PRI (virtual chassis primary)
• BPS (backup power status)
• STK (stacking indicator for 10 port models)
• PWR (primary power supply status)
• PRI (virtual chassis primary)
• BPS (backup power status)
• STK (stacking indicator for 10 port models)
per-port leds
• 10/100/1000: PoE, link/activity
• SFP: Link/activity
• Stacking: Link/activity
• SFP: Link/activity
• Stacking: Link/activity
compliance and certifications
commercial
EMI/EMC
EMI/EMC
• FCC CRF Title 47 Subpart B (Class A limits.
Note: Class A with UTP cables)
• VCCI (Class A limits. Note: Class A with
UTP cables)
• AS/NZS 3548 (Class A limits. Note: Class A
with UTP cables)
• CE marking for European countries (Class
A limits. Note: Class A with UTP cables)
• EN 55022: 2006 (Emission Standard)
• EN 61000-3-3: 1995
• EN 61000-3-2: 2006
• EN 55024: 1998 (Immunity Standards)
• EN 61000-4-2: 1995+A1: 1998
• EN 61000-4-3: 1996+A1: 1998
• EN 61000-4-4: 1995
• EN 61000-3-3: 1995
• EN 61000-3-2: 2006
• EN 55024: 1998 (Immunity Standards)
• EN 61000-4-2: 1995+A1: 1998
• EN 61000-4-3: 1996+A1: 1998
• EN 61000-4-4: 1995
• EN 61000-4-5: 1995
• EN 61000-4-6: 1996
• EN 61000-4-8: 1994
• EN 61000-4-11: 1994
• IEEE 802.3: Hi-Pot Test (2250 V
• EN 61000-4-6: 1996
• EN 61000-4-8: 1994
• EN 61000-4-11: 1994
• IEEE 802.3: Hi-Pot Test (2250 V
DC on all Ethernet ports)
Safety agency certifications
• US UL 60950
• IEC 60950-1:2001; all national deviations
• EN 60950-1: 2001; all deviations
• CAN/CSA-C22.2 No. 60950-1-03
• NOM-019 SCFI, Mexico
• AS/NZ TS-001 and 60950:2000, Australia
• UL-AR, Argentina
• UL-GS Mark, Germany
• EN 60825-1 Laser, EN 60825-2 Laser
• CDRH Laser
• IEC 60950-1:2001; all national deviations
• EN 60950-1: 2001; all deviations
• CAN/CSA-C22.2 No. 60950-1-03
• NOM-019 SCFI, Mexico
• AS/NZ TS-001 and 60950:2000, Australia
• UL-AR, Argentina
• UL-GS Mark, Germany
• EN 60825-1 Laser, EN 60825-2 Laser
• CDRH Laser