Adtran SFP 100Base-TX RJ-45 100m 1442200G1 전단
제품 코드
1442200G1
Warranty:
ADTRAN will replace or repair this product within the warranty period if it does not meet
www.adtran.com/warranty
.
©2010 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S.
1.800.726.8663
From outside the U.S.
1.256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442200G1-22A*
C
OMPLIANCE
!
CAUTION
♦
Electrostatic Discharge (ESD) can damage electronic modules.
When handling electronic components, wear an antistatic
discharge wrist strap to prevent damage. Place modules in
antistatic packing material when transporting or storing. When
working on modules, always place them on an approved
antistatic mat that is electrically grounded.
When handling electronic components, wear an antistatic
discharge wrist strap to prevent damage. Place modules in
antistatic packing material when transporting or storing. When
working on modules, always place them on an approved
antistatic mat that is electrically grounded.
♦
The SFPFC is NRTL listed to all applicable UL standards. The
SFPFC meets or exceeds all applicable requirements of NEBS,
Telcordia GR‐63‐CORE, GR‐78‐CORE, and GR‐1089‐CORE. The
SFPFC is intended for deployment in Central Office type
facilities, EEEs, EECs, and locations where the NEC applies
(e.g., Customer Premises).
SFPFC meets or exceeds all applicable requirements of NEBS,
Telcordia GR‐63‐CORE, GR‐78‐CORE, and GR‐1089‐CORE. The
SFPFC is intended for deployment in Central Office type
facilities, EEEs, EECs, and locations where the NEC applies
(e.g., Customer Premises).
♦
The SFPFC should be installed by qualified Service Personnel
only, in an ADTRAN module intended for installation in an
ADTRAN host system located in a restricted access location.
only, in an ADTRAN module intended for installation in an
ADTRAN host system located in a restricted access location.
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
subject to the following two conditions:
1.
This device may not cause harmful interference.
2.
This device must accept any interference received, including
interference that may cause undesired operation.
interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN
could void the user’s authority to operate this equipment.
could void the user’s authority to operate this equipment.
!
CAUTION
♦
Per GR‐1089‐CORE the SFPFC is designed and intended for
installation as part of a Common Bonding Network (CBN). The
SFPFC is not designed nor intended for installation as part of an
Isolated Bonding Network (IBN).
installation as part of a Common Bonding Network (CBN). The
SFPFC is not designed nor intended for installation as part of an
Isolated Bonding Network (IBN).
♦
Per GR‐1089‐CORE, Section 9, the SFPFC does not have an
internal DC connection between –48 VR and frame ground.
The SFPFC can be deployed in an Isolated (DC‐I) or Common
(DC‐C) configuration. For installations where other modules or
the host system have internal connections between –48 VR and
frame ground, the system would be intended for deployment
only in a DC‐C configuration.
internal DC connection between –48 VR and frame ground.
The SFPFC can be deployed in an Isolated (DC‐I) or Common
(DC‐C) configuration. For installations where other modules or
the host system have internal connections between –48 VR and
frame ground, the system would be intended for deployment
only in a DC‐C configuration.
♦
The host chassis frame ground terminal must be connected to
an earth ground to ensure that the metal enclosure of the
SFPFC is properly grounded via the backplane connector.
an earth ground to ensure that the metal enclosure of the
SFPFC is properly grounded via the backplane connector.
WARNING
!
♦
The Ethernet port is classified as Type 2 or Type 4, as defined in
GR‐1089‐CORE, Issue 5, Appendix B, and is suitable for
connection to intrabuilding or unexposed wiring or cabling
only. Do not metallically connect this port to any interface
which connects to the Outside Plant (OSP) or to the OSP wiring.
The addition of Primary Protectors is not sufficient protection in
order to connect this interface metallically to OSP wiring.
GR‐1089‐CORE, Issue 5, Appendix B, and is suitable for
connection to intrabuilding or unexposed wiring or cabling
only. Do not metallically connect this port to any interface
which connects to the Outside Plant (OSP) or to the OSP wiring.
The addition of Primary Protectors is not sufficient protection in
order to connect this interface metallically to OSP wiring.
♦
The Ethernet port is suitable for connection only to shielded
intra‐building cabling, grounded at both ends.
intra‐building cabling, grounded at both ends.
NOTE
The SFPFC is designed for deployment in GR‐3108‐CORE
environmental class 1 and 2, as defined in GR‐3108‐CORE, Issue 2.
environmental class 1 and 2, as defined in GR‐3108‐CORE, Issue 2.
The SFPFC is designed to meet the following environmental
classes:
classes:
♦
ETSI EN 300 019‐1‐1 “Classification of environmental
conditions; Storage,” Class 1.2
conditions; Storage,” Class 1.2
♦
ETSI EN 300 019‐1‐2 “Classification of environmental
conditions; Transportation,” Class 2.3
conditions; Transportation,” Class 2.3
♦
ETSI EN 300 019‐1‐3 “Classification of environmental
conditions; Stationary use at weather‐protected locations,”
Class 3.3
conditions; Stationary use at weather‐protected locations,”
Class 3.3
The equipment is designed to function without degradation
during exposure to all test severities per Class 019‐1‐3 3.3.
during exposure to all test severities per Class 019‐1‐3 3.3.
The SFPFC complies with ETSI EN 300 386 “Electromagnetic
compatibility and Radio spectrum Matters (ERM);
Telecommunication network equipment;
Electromagnetic Compatibility (EMC) requirements.”
compatibility and Radio spectrum Matters (ERM);
Telecommunication network equipment;
Electromagnetic Compatibility (EMC) requirements.”
The SFPFC meets the EU RoHS Directive 2002/95/EC and/or
applicable exemptions. For more information on RoHS/WEEE,
refer to
applicable exemptions. For more information on RoHS/WEEE,
refer to
www.adtran.com
.
C A U T I O N
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.