CAUTION:  To reduce the risk of electric shock,
Do not remove cover.
No user serviceable parts inside.
Refer servicing to qualified service personnel.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
ISSUE 3
VIP-820
NETWORKED TRUNK PORT
INTRODUCTION
The VIP-820 networked trunk port allows an analog
PBX Station Port to be connected to a managed IP-
based Local Area Network ( LAN) or Wide Area
Network (WAN).
SPECIFICATIONS
Access Methods
• 
PBX Station port (FXS) with open loop
disconnect signal provided
Features
• 
RJ-45 for network connection
• 
RJ-11 telephone connection
• 
Front panel activity LED
• 
Network activity LEDs on RJ-45
• 4 
RENS
• 
2.5mm jack for DC power (115VAC TO 24VDC
adapter provided)
Dimensions/Weight
•  1.88" H x 5.50" W x 4.15" D
     (4.78cm H x 13.97cm W x 10.54cm D)
•  Weight:   0.55 lbs.  (0.25 kg)
Nominal Specifications
Input Impedance:
600 Ohms
Input Level:
-10dBm
Output Impedance:
600 Ohms
Output Level:
- 10dBm nominal
Nominal Power Requirements
Voltage:  
  24VDC
Current:  
  325mA
         
Environment
Temperature:
                          0 to +40 Degrees C
Humidity:    
               0 to 85% non-precipitating
INSTALLATION
NOTE:  The telephone system referred to in this
manual is the customer premise equipment such as
an electronic key system, a PBX or a dedicated single
line telephone sets.  The VIP-820 is not intended for
direct or indirect connection to the public telephone
network.  When used with a customer premise
telephone system such as a key system or PBX
system, these units are interfaced to the system via a
fully protected Extention /Station Port (FXS) port,
which is fully  protected interface device.  Also, the
host system must be configured to disallow central
office trunk conferencing in order to prevent indirect
connection to the public network.
   Precautionary Designations
Mounting
The VIP-820 was designed for wall or table mounting.
Secure unit to wall studs or a suitable brace away
from heat sources or strong magnetic fields (motors,
fans, power supplies, etc.) with the control and
terminal strip accessible.  One wood screw is included
for mounting.
Power Connections
NOTE:  This equipment must be installed near an
AC power outlet due to the power cord being used
as a disconnect device.
The VIP-820 is provided with a VP-324 for North
American use.
After all required connections have been made,
plug the VP-324 into appropriate AC wall outlet.