Toshiba Strata GVMU/LVMU 사용자 설명서

다운로드
페이지 103
Notes to Users
Step 1: Safety Approval
74
Strata LVMU/GVMU Voice Processing System User Guide    7/06
SELV
PDKU2A/BDKU/BDKS/
BWDKU
For connection of Toshiba proprietary terminals.
SELV
BSIS1A
For connection of Voice Mail and Call Logging 
Equipment. RS232 ports.
TNV3
RSTU1F/RSTU3F/BSTU1F/
BSLU1F/BSLS1F/ASTU1F/
LSLU
For connection of Approved 2 wire devices.
TNV3
PCOU2F/PCOUS2FRCOU/
RCOS/RCOUS
For connection to PTO provided Loop Calling 
Unguarded Clear exchange lines.
TNV1
RBSU1A/ RBSU2A
2 Cct ISDN2, (TBR3), Basic Rate I/F. For connection 
to euro-ISDN services.
TNV1
RBSS1A & RBSS2A
2 Cct ISDN2, (TBR3), Basic Rate I/F. For connection 
to approved Euro-ISDN services & devices.
TNV1
RPTU1F/RPTU2F/BPTU1F
1 ccts ISDN30, (TBR4), primary rate I/F. For 
connection to euro-ISDN services..
TNV2
PACU2F/PACU3F
4 Cct AC15 Private Circuit I/F, (TBR17). For 
connection to PTO Private Circuit services.
TNV2
PEMU2F/REMU
4 Cct DC5 Private Circuit I/F, (TBR 17). For 
connection to PTO Private Circuit services.
SELV
BIOU1A
Contains various ports for connection of audio 
paging amplifiers, dry relay contacts to control 
external equipment.
SELV
BVPU1A/BIPUM2A/ 
BIPQ1A/LIPU-X1A
Voice Over IP interface cards. House Ethernet/
RS232 ports
SELV
Stratagy DK, IES32, 
GVMU1F, LVMU1F
Integrated Voice Mail unit. Houses R232 ports.
SELV
RRCU1A
Optical interface board for connecting remote 
cabinets.
SELV
BPCI1A
USB port for connection of PC for CTI
SELV 
DKT2500/DKT3000/
DKT3500/IPT1020/
DKT3200/IPT2000
Headset ports on any of the range of key telephones.
TNV3
LPFU1A
8 port power failure Transfer Unit for BSTU and 
RCOU units.
TNV3
LCNU-C1A, LCNU-D1A
Passive extender units for CIX product
Table A-1
(continued)
Type of Circuit 
(EN60950 
Classification)
Port Location
Port Description
Get user manuals: 
See SafeManuals.com