Toshiba VF-AS1 사용자 설명서

다운로드
페이지 326
!
  E6581301!
A-3 
■ Operation panel 
RUN key lamp 
Lights when the RUN 
key is enabled.   
RUN key 
Pressing this key 
while the RUN key 
lamp is lit starts the 
operation.   
Pressing this key while 
the RUN key lamp is lit 
causes the motor to make 
a deceleration stop. Press 
the key twice to reset the 
inverter after a trip. 
STOP key 
Up/Down key lamp 
With these keys, you 
can set the operation 
frequency while the 
Up/Down key lamp is 
lit. [Note 2] 
2-wire RS485 connector. This 
connector is used to connect an 
optional device, such as an 
extended control panel. 
Up key 
Down key 
RUN lamp 
Lights when an ON 
command is issued but no 
frequency signal is sent 
out. It blinks when 
operation is started.   
MODE key 
Displays the operation 
frequency, a 
parameter, the cause 
of a failure, and so on.
MON lamp 
Lights when the 
inverter is in monitor 
mode. Blinks when the 
inverter is placed in trip 
record display mode. 
PRG lamp 
Lights when the 
inverter is in parameter 
setting mode. 
ENTER key 
EASY key lamp
Lights when the EASY 
key is enabled. 
EASY key [Note 1]
Press this key to control 
the function assigned 
with a parameter.
% lamp 
Lights when the unit 
is %.   
Hz lamp 
Lights when the unit is 
Hz. 
RS485 connector/cover 
Note 1: Ÿ For details EASY Key functions, refer to Section 5.22. 