DeVillbiss Air Power Company A16064 사용자 설명서

다운로드
페이지 56
16- ENG 
A16064
TROUBLE SHOOTING GUIDE
PROBLÈME
CAUSE
CORRECTION
Engine will 
not start (see 
Engine Manual 
for further 
engine trouble-
shooting)
No fuel.
Add Fuel.
Pressure builds up after two 
pulls on the recoil starter or 
after initial use.
Squeeze gun trigger to relieve 
pres sure.
Choke lever in the "No 
Choke" position.
Move choke to the "Choke"
po si tion.
Spark plug wire not 
attached.
Attach spark plug wire.
Engine ON/OFF switch in 
OFF po si tion.
Place engine ON/OFF switch 
in ON position.
Choke lever in the "Choke" 
position on a "hot" engine 
or an engine that has been 
exposed to thermal heat for 
a long period of time.
Move choke to the "No 
Choke" po si tion.
Fuel valve closed
Move the fuel valve lever to 
the "Open" position.
No or low 
pressure 
(initial use)
Spray wand not in high 
pressure.
See How to Use Spray Wand 
instructions in the Operation 
Section.
Low water supply.
Water supply must be at least  
5 GPM @ 20 PSI (137.9 kPa).
Leak at high pressure hose 
fitting.
Repair leak. Apply sealant 
tape if necessary.
Nozzle obstructed.
See Nozzle Cleaning 
instructions in the 
Maintenance section.
Water filter screen clogged.
Remove and clean filter.
Air in hose.
Turn off the engine, then the 
water source. Disconnect the 
water source from the pump 
inlet and turn the water source 
on to remove all air from the 
hose. When there is a steady 
stream of water present, turn 
water source off. Re- con nect 
water source to pump inlet 
and turn on wa ter source. 
Squeeze trigger to re move 
re main ing air
Choke lever in the "Choke" 
position.
Move choke to the "No 
Choke" po si tion.
High pressure hose is too 
long.
Use high pressure hose under 
100 feet.